background image

En-2

 WARNING

•  This product shall be stored in a room without 

continuously operating ignition sources (for example: 

open fl ames, an operating gas appliance or an 

operating electric heater).

•  This product shall be stored in a well-ventilated area.

•  Be aware that refrigerants may not contain an odour.
•  This product shall be stored so as to prevent 

mechanical damage from occurring.

•  Disposing of the product shall be done properly, in 

compliance with national or regional regulations.

•  This product is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision 

or instruction concerning use of this product by a 

person responsible for their safety.

Children should be supervised to ensure that they do 

not play with this product.

•  Do not move this product by holding the indoor unit pipes.

(The stress applied to the pipe joints may cause the 

fl ammable gas to leak during operation).

•  Do not install the unit in area fi lled with mineral oil 

such as a factory or area containing a large amount of 

splashed oil or steam such as a kitchen.

•  Do not start or stop the operation of this product by 

turning on or off  the circuit breaker.

•  Do not use fl ammable gases near this product.
•  Do not expose yourself directly to the cooling airfl ow 

for many hours.

•  Do not insert your fi ngers or any other objects into 

outlet port or inlet grille.

•  Do not operate with wet hands.
•  Do not use means to accelerate the defrosting 

process or to clean this product, other than those 

recommended by the manufacturer.

•  Do not pierce or burn.

 CAUTION

•  Provide occasional ventilation during use.
•  Always operate this product with air fi lters installed.
•  Ensure that any electronic equipment is at least 1 m (40 

in) away from this product.

•  Disconnect all the power supply when not using this 

product for extended periods.

•  After a long period of use, ensure to get the mounting 

of the indoor unit checked to prevent this product from 

falling down.

•  The airfl ow direction and the room temperature should 

be carefully considered when you use this product in a 

room with infants, children, elderly or sick persons.

•  Keep the surroundings of the outdoor unit clean and 

tidy, and do not place items around it. Any objects 

blocking or entering from the outlet ports may cause 

product malfunction.

•  Do not direct the airfl ow at fi replaces or heating apparatus.
•  Do not block or cover the intake grille and the outlet port.
•  Do not apply any heavy pressure to radiator fi ns.
•  Do not climb on, place objects on, or hang objects 

from this product.

 CAUTION

•  Do not place any other electrical products or 

household belongings under this product. Dripping 

condensation from this product might get them wet, 

and may cause damage or malfunction of your 

property.

•  Do not expose this product directly to water.
•  Do not use this product for preservation of food, plants, 

animals, precision equipment, art work, or other objects. 

This may cause quality deterioration of those items.

•  Do not expose animals or plants to the direct airfl ow.
•  Do not drink the drainage from the air conditioner.
•  Do not pull the power supply cable.
•  Do not touch the aluminum fi ns of heat exchanger 

built-in this product to avoid personal injury when you 

install or maintain the unit.

•  Do not stand on unstable steps when operating or 

cleaning this product. It may overturn and can cause 

injury.

2.  BASIC OPERATIONS

NOTES:

 For detailed instructions on how to operate, please refer to the 

operating manual of the remote controller.

The operation mode and the temperature setting range are 

shown in the following table.

Operation mode

Temperature setting range

Auto

18.0 - 30.0 °C

Cooling

18.0 - 30.0 °C

Dry

18.0 - 30.0 °C

Fan

You cannot set the temperature.

Heating

16.0 - 30.0 °C

 

Auto mode

The air conditioner selects the appropriate operation mode 

(Cooling or Heating) according to your room’s present 

temperature.

Room temperature

Operation

Higher than the setting temperature

Cooling

Close to the setting temperature

Determined by outdoor 
temperature

Lower than the setting temperature

Heating

Defi ned temper-
ature in tempera-
ture setting 

Determined by 
outdoor temperature 

Cooling mode

Heating mode

When Auto mode is fi rst selected, the fan will operate at low speed for 
about a few minutes, during which time the indoor unit detects the room 
conditions and selects the operation mode.
When the air conditioner has adjusted your room’s temperature to near 
the thermostat setting, it will begin monitor operation.
In the monitor operation mode, the fan will operate at low speed. If the 
room temperature subsequently changes, the air conditioner will once 
again select the appropriate operation (Heating, Cooling) to adjust the 
temperature to the value set in the thermostat. 
If the mode automatically selected by the unit is not what you wish, 
select one of the mode operation (Heating, Cooling, Dry, Fan).

9383813009_OM.indb   2

9383813009_OM.indb   2

12/12/2018   9:03:03 AM

12/12/2018   9:03:03 AM

Summary of Contents for ARXG12-54KHTAP

Page 1: ...ΣΤΙΚΟ Τύπος αγωγού Προτού χρησιμοποιήσετε το προϊόν διαβάστε προσεκτικά τις παρούσες οδηγίες και φυλάξτε το παρόν εγχειρίδιο ώστε να μπορείτε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo conduta Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Канального типа...

Page 2: ...lways consult authorized service personnel for repairing installation and relocation of this product Improper installation or handling will cause leakage electric shock or fire In the event of a malfunction such as burning smell immediately stop operation of the air conditioner and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug Then consult auth...

Page 3: ...aces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product CAUTION Do not place any other electrical products or household belongings under this product Dripping condensation from this product might get them wet and may cause damage or malfunction of your pr...

Page 4: ...an the current room temperature otherwise the fan alone will operate The indoor unit fan may stop from time to time because of the Fan control for energy saving refer to page 4 Dry mode Use for gently cooling while dehumidifying your room NOTES You cannot heat the room Set the temperature lower than the current room temperature otherwise the operation will not operate The unit will operate at low ...

Page 5: ...n by using the wireless remote controller cannot be used 10 C Heat operation maintains the room temperature at 10 C so as to prevent the room temperature to drop too low NOTES When the room temperature is warm enough This operation will not be performed In case of multi type air conditioner if other indoor unit is used for heating the temperature of the room where the 10 C Heat operation is applie...

Page 6: ...tructions on how to operate please refer to the operating manual of the remote controller 8 GENERAL INFORMATION Inverter On start up the air conditioner will operate at maximum capacity to bring the room quickly down to desired temperature Once the temperature in the room begins to achieve the set temperature the air conditioner will reduce its capacity and energy usage to the minimum capacity and...

Page 7: ...ectable indoor units and connectable type of the separation tube vary by model Depending on model this function cannot be used For details please consult authorized service personnel In simultaneous multi connection all indoor units can be operated simultaneously from one remote controller connected to the primary indoor unit For this unique characteristic of the simultaneous multi connection the ...

Page 8: ...mode Do you hear a sizzling sound This sound is produced by the Automatic defrosting operation Refer to page 5 Smell coming from the unit The air conditioner may absorb various smells generated from interior textile furniture or cigarette smoke These smells may be emitted during the operation Mist or steam is emitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensa...

Reviews: