- 58 -
O
U
T
D
OOR UNIT
AOY
G
30, 36
LMTA
6. Additional charge calculation
6-1. Model: AOYG30LMTA
Refrigerant charge
6-2. Model: AOYG36LMTA
Refrigerant charge
Refrigerant type
R410A
Refrigerant amount
g
2,100
Total pipe length
m
20 or less
30
40
50 (Max.)
40 g/m
Additional charge
g
0
400
800
1,200
Refrigerant type
R410A
Refrigerant amount
g
2,100
Total pipe length
m
20 or less
30
40
50 (Max.)
40 g/m
Additional charge
g
0
400
800
1,200