12. OPTIONAL KIT INSTALLATION (OPTION)

This air conditioner can be connected with the following optional kits. Refer to each instal-
lation manual for the method of installing parts.
•  Wired remote controller
•  Simple remote controller
•  External connect kit

12.1. Before install optional remote controller

•  When you use optional remote controller, some functions may not be used.
•  Please use the recommended optional remote controller.

 CAUTION

Before installing, be sure to disconnect all power supply.

Don’t touch the heat exchanger.

During installing or removing operation, be sure not to have wire caught by parts 
or draw it hard. Or it may result troubles to the air-conditioner.

Avoid place in direct sunlight.

Select place that will not be affected by the heat from a stove, etc.

Before setting up the optional kit, please con

fi

 rm whether air-conditioner can 

receive the signal.

Do not connect the optional remote controller to the terminal for power supply.

When connecting the optional remote controller with the indoor unit, please use 
the connecting cable packaged up with the optional remote controller.

Recommended cable length of optional remote controller is 10 m. Make sure to 
do insulate of connecting part when extended the cable.

]

1

12.2. Remote controller cable modi

fi

 cation

(1)  Use a tool to cut off the terminal on the end of the remote controller cable, and then 

remove the insulation from the cut end of the cable.

(2)  Connect the remote controller cable and connecting cable. (Supplied with wired remote 

controller) 

Important:

  Be sure to solder wires to connect. Be sure to insulate the connection between the 

wires.

Connecting cable

White

Red

White

Red

Black

Black

Insulated
connection

Remote
controller cable

Remote
controller cable

20 mm 

12.3.  External input / output Wire modi

fi

 cation

(1)  Remove insulation from wire attached to wire kit 

connector. Remove insulation from 

fi

 eld supplied 

cable. Use crimp type insulated butt connector to 
join 

fi

 eld cable and wire kit wire.

(2)  Connect the wire and Field supply wire. 

(Supplied with external connect kit)

Important:

Be sure to solder wires to connect. Be sure to 
insulate the connection between the wires.

Option parts 
External input/
output wire

Cable 
(Field supply)

Insulated 
connection

10. TEST RUN

 WARNING

Do not turn on the power until all installation work is complete.

 CAUTION

When restarting after a long period of disuse in the winter, turn the power switch on at least 
12 hours before starting the unit.

Check items

(1)  Is operation of each button on the remote controller normal?
(2) Does each lamp light normally?

(3) Do air 

fl

 ow direction louvers operate normally?

(4) Is the drain normal?
(5)  Do not have an error noise and vibration during operation?

 Do not operate the air conditioner in test run for a long time.

[Operation method]

  For the operation method, refer to the operating 

manual.

  The outdoor unit may not operate depending on 

the room temperature. In this case, press the 
test run button on the remote controller while the 
air conditioner is running. (Point the transmitter 
section of the remote controller toward the air 
conditioner and press the test run button with the 
tip of a ballpoint pen, etc.)

  To end test operation, press the remote controller 

START/STOP button. (When the air conditioner 
is running by pressing the test run button, the 
OPERATION Lamp and TIMER Lamp will 
simultaneously 

fl

 ash slowly.)

[Using the wired remote control] (Option)

  For the operation method, refer to the operating 

manual.

(1) Stop the air conditioner operation.
(2)  Press the master control button and the fan 

control button simultaneously for 2 seconds or 
more to start the test run.

(3) Press the start/stop button to stop the test run.

11. REMOTE CONTROLLER INSTALLATION

 CAUTION

Check that the indoor unit correctly receives the signal from the remote controller, 
then install the remote controller holder.

Select the remote controller holder selection site by paying careful attention to 
the following:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat from a stove, etc.

11.1.

 

Remote controller holder installation

•  Install the remote controller a maximum distance of 7 m from the remote control re-

ceiver. However, when installing the remote controller, check that it operates correctly.

•  Install the remote controller holder to a wall, pillar, etc. with the tapping screw.

Remote controller holder 

fi

 xing

Remote controller mounting

Remote controller 
holder

Tapping screw 
(M3 x 12 mm)

Remote 
controller

(1) Set

(2) Push

Transmitter section

Test run button

Test run display

9318739084_IM.indb   7

9318739084_IM.indb   7

9/27/2012   1:43:55 PM

9/27/2012   1:43:55 PM

Summary of Contents for AOYG18LFC

Page 1: ...e autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Μόνο για εξουσιοδοτημένο προσωπικό του σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos de assistência autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Только для авторизованного обслуживающего персонала MONTAJ KILAVUZU Sadece yetkili servis personeli içindir INSTALLATION MANUAL AIR CONDITIONER INDOOR UNIT Wall Mounted Type PART NO 9318739084 h c s t u e D s i a ç n a r F...

Page 2: ... port thread diameter to prevent erroneous charging with conventional refrigerant R22 and for safety Therefore check beforehand The charging port thread diameter for R410A is 1 2 inch Be more careful that foreign matter oil water etc does not enter the piping than with refrigerant R22 models Also when storing the piping securely seal the opening by pinching taping etc When charging the refrigerant...

Page 3: ...arts Parts name Model No Application Wired Remote Controller UTY RNN M For air conditioner operation Simple Remote Controller UTY RSN M For air conditioner operation External connect kit UTY XWZX For control input output port 3 GENERAL This INSTALLATION MANUAL briefly outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and ou...

Page 4: ...e installed more than 1 m apart you could still receive noise under some signal conditions If children under 10 years old may approach the unit take preventive measures so that they cannot reach the unit Install the indoor unit on the wall where the height from the floors more than 1800 mm 6 INSTALLATION WORK 1 6 1 Installation dimensions Remote controller Remote controller holder Tapping screw sm...

Page 5: ...r piping and drain hose through the wall hole hang the indoor unit on the hooks at the top and bottom of the wall hook bracket Installing the indoor unit Hang the indoor unit from the hooks at the top of the wall hook bracket Insert the spacer etc between the indoor unit and the wall hook bracket and separate the bottom of the indoor unit from the wall Indoor unit Wall hook bracket Spacer Wall hoo...

Page 6: ...wire must be connected firmly No wire should be allowed to touch refrigerant tubing the compressor or any moving part Loose wiring may cause the terminal to overheat or result in unit malfunction A fire hazard may also exist Therefore be sure all wiring is tightly connected Connect wires to the matching numbers of terminals 7 2 Indoor unit wiring 1 Remove the cable clamp 2 Bend the end of the conn...

Page 7: ...n pipe heat insulation Vinyl tape Indoor unit pipe heat insulation Wrap with cloth tape Pipe Drain hose Cloth tape Left piping Connection cable Pipe Drain hose For connection from the left rear Connection cable Wall pipe Connection pipe Drain hose Check the following GOOD Saddle Drain hose Lifted up Wave End in water PROHIBITED 1 9 FRONT PANEL REMOVAL AND INSTALLATION 9 1 Intake grille removal 1 O...

Page 8: ...rts External input output wire Cable Field supply Insulated connection 10 TEST RUN WARNING Do not turn on the power until all installation work is complete CAUTION When restarting after a long period of disuse in the winter turn the power switch on at least 12 hours before starting the unit Check items 1 Is operation of each button on the remote controller normal 2 Does each lamp light normally 3 ...

Page 9: ...de Use the following steps to select the signal code of the re mote controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code The signal codes that are set through this process are ap plicable only to the signals in the FUNCTION SETTING For details on how to set the signal codes through the normal process refer to Remote contr...

Page 10: ...onditioner signal code setting try each of the signal codes until you find the code which operates the air conditioner 14 CUSTOMER GUIDANCE Explain the following to the customer in accordance with the operating manual 1 Starting and stopping method operation switching temperature adjustment timer air flow switching and other remote control unit operations 2 Air filter removal and cleaning and how ...

Page 11: ...door unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7 3 Outdoor unit Heat Ex liquid temp sensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error 7 6 2 way valve ...

Reviews: