Fujitsu AOYG14LTCN Installation Manual Download Page 8

En-8

REMOTE CONTROLLER INSTALLATION

11. 

 CAUTION

Check  that  the  indoor  unit  correctly  receives  the  signal  from  the  remote  controller, 
then install the remote controller holder.
Select the remote controller holder selection site by paying careful attention to the fol-
lowing:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat from a stove, etc.

 Remote controller holder installation

11. 1. 

!

  Install the remote controller a maximum  distance of 6 m  from the remote control signal 

receiver.  However,  when  installing  the  remote  controller,  check  that  it  operates  cor-
rectly.

!

  Install the remote controller holder to a wall, pillar, etc. with the tapping screw.

Remote controller 
holder 

Þ

 xing

Remote controller 
mounting

Remote controller 
holder

Tapping 
screw 
(small)

(1) Set

Remote 
controller

(2) Down

OPTIONAL KIT INSTALLATION (UTY-TWBXF)

12. 

This air conditioner can be connected with the following optional kits.
 •  Wired remote controller
 •  Simple remote controller
 •  External connect kit

BEFORE INSTALL WIRED REMOTE CONTROLLER

 •  When you use wired remote controller, some functions may not be used.

 CAUTION

Before installing, be sure to disconnect all power supply.

Don’t touch the heat exchanger.

During installing or removing operation, be sure not to have wire catched by parts or 
draw it hard. Or it may result troubles to the air-conditioner.

Avoid place in direct sunlight.

Select place that will not be affected by the heat from a stove, etc

 Before setting up the optional kit, please con

Þ

 rm whether air-conditioner can receive 

the signal.

Do not connect the wired remote controller to the terminal for power supply.

 When connecting the wired remote controller with the indoor unit, use the connecting 
cable (supplied with wired remote controller or simple remote controller).

 Recommended cable length of wired remote controller is 10 m. Make sure to do insu-
late of connecting part when extended the cable.

Do not connect power supply with the terminal.

INDOOR UNIT

PCB

TERMINAL

Front panel installation

9. 4. 

(1)  First, 

Þ

 t  the  lower  part  of  the  front  panel,  and  insert  top  and  bottom  hooks.  (2  top 

sides, 7 bottom sides, 2 center)

Indoor unit

Bottom holes

(3 position)

Bottom hooks

(3 position)

Bottom holes

(4 position)

Center holes

(2 position)

Center hooks

(2 position)

Top hooks

(2 position)

Top holes

(2 position)

Indoor unit

Front panel

Bottom hooks

(2 position)

Bottom hooks
(2 position)

Front panel

(2) Attach the 4 screws.
(3) Attach the wire cover. (Attach the 1 screw.)
(4) Attach the intake grille.

 CAUTION

Install the Front panel and Intake grille securely. If installation is imperfect, the Front 
panel or Intake grille may fall off and cause injury.

TEST RUN

10. 

Check items

(1)  Is operation of each button on the remote controller unit normal?
(2)  Does each lamp light normally?
(3)  Do air

ß

 ow direction louvers operate normally?

(4)  Is the drain normal?
(5)  Do not have an abnormal noise and vibration during operation?

!

 

Do not operate the air conditioner in test run for a long time.

[Operation method]

!

  For the operation method, refer to the operating manual.

!

   The outdoor unit, may not operate, depending on the room temperature. In this case, 

keep on pressing the MANUAL AUTO button of the indoor unit for more than 10 
seconds. The OPERATION indicator lamp (green) and TIMER indicator lamp (orange) 
will begin to 

ß

 ash simultaneously during cooling test run. Then, heating test run will 

begin in about 3 minutes when HEAT is selected by the remote control operation. (Please 
follow the operating manual for remote control operation.)
(When the air conditioner is running by pressing the test run button, the OPERATION 
indicator lamp and TIMER indicator lamp will simultaneously 

ß

 ash slowly.)

Press and hold MANUAL AUTO 
button for 10 seconds

MANUAL AUTO button

!

 

When ending the test run, keep on pressing the MANUAL AUTO button of the indoor 
unit for more than 3 seconds.

[Using the wired remote controller] (Option)

For the operation method, refer to the operating manual.
(1)  Stop the air conditioner operation.
(2)  Press the MODE button and the FAN button simultaneously for 

2 seconds or more to start the test run.

Test run display

(3)  Press the start/stop button to stop the test run.

Summary of Contents for AOYG14LTCN

Page 1: ... Swedish Polish AIR CONDITIONER ASENNUSOHJE SISÄYKSIKKÖ seinälle asennettava malli Vain valtuutetuille huoltohenkilöille INSTALLASJONSVEILEDNING INNENDØRSENHET veggmontert modell Kun for autorisert servicepersonell INSTALLATIONSHANDBOK INOMHUSENHET väggmonterad Endast för auktoriserad servicepersonal INSTRUKCJA MONTA U URZ DZENIE WEWN TRZNE do monta u ciennego Do u ytku wy cznie przez autoryzowany...

Page 2: ...use damage or malfunction of your property ABOUT THE UNIT 2 Precautions for using R410A refrigerant 2 1 The basic installation work procedures are the same as conventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools a...

Page 3: ...s to secure refrigerant piping ELECTRICAL REQUIREMENT 4 The indoor unit is powered from the outdoor unit or branch box Do not power indoor unit from separate power source WARNING Refer to local codes for acceptable cable type Cable Cable size Remarks Connection cable Type 60245 IEC 57 3 cable Ground 1 Ø 230 V Max Cable Length Limit voltage drop to less than 2 Increase cable gauge if voltage drop i...

Page 4: ...g When the piping is connected in direction 2 3 4 or 5 use a cutting tool to cut along the groove for the piping that will coming out of the under cover For 5 Left outlet For 4 Left bottom outlet For 3 Right bottom outlet For 2 Right outlet Cutting the hole in the wall for the connecting piping 6 6 1 Cut a 65 mm diameter hole in the wall at the position shown in the following 2 Cut the hole so tha...

Page 5: ... and left rear piping align the marks on the wall hook bracket and shape the connection pipe Bend the connection piping at a bend radius of 70 mm or more and install no more than 35 mm from the wall After passing the indoor piping and drain hose through the wall hole hang the indoor unit on the hooks at the top and bottom of the wall hook bracket No gap Hexagonal wrench Drain cock Drain cap Instal...

Page 6: ... line Type 245 IEC57 Inter unit OUTDOOR UNIT or BRANCH BOX Please connect it to the speciÞed terminal INDOOR UNIT TERMINAL Power line Control line Indoor unit wiring 7 2 1 Remove the wire cover Remove the 1 screw 2 Remove the cable clamp Remove the 1 screw 3 Bend the end of the connection cable as shown in the Þgure 4 Connect the end of the connection cable fully inserting into the terminal block ...

Page 7: ...e Connection cable Pipe Drain hose Check the following GOOD Drain hose Saddle Lifted up Wave End in water Drain hose Connection pipe Wall pipe Connection cable Left piping For connection from the left rear NO GOOD NO GOOD NO GOOD Pipe Connection pipe heat insulation Bind the pipes together so that there is no gap Indoor unit pipe heat insulation FRONT PANEL REMOVAL AND INSTALLATION 9 Intake grille...

Page 8: ...R UNIT PCB TERMINAL Front panel installation 9 4 1 First Þt the lower part of the front panel and insert top and bottom hooks 2 top sides 7 bottom sides 2 center Indoor unit Bottom holes 3 position Bottom hooks 3 position Bottom holes 4 position Center holes 2 position Center hooks 2 position Top hooks 2 position Top holes 2 position Indoor unit Front panel Bottom hooks 2 position Bottom hooks 2 p...

Page 9: ...CN8 Relay wire Notice 2 Clasp Connector CND01 Relay control board Clasps 2 Notice the installing direction of the relay control board The elevation of the control box is fit for the recess of the relay control board 1 Insert the relay control board toward 2 clasps 2 Then set the board with the clasp 3 Connect the relay wire terminal to the connector CND01 on the relay control board 4 Connect the r...

Page 10: ...ding on the installed environment the room temperature sensor may require a cor rection The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Slightly lower control 01 Lower control 02 Warmer control 03 Function number Setting value Installing the external connect kit terminal sold separately Connect the wire of ex...

Page 11: ...nsor error 7 5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error Heating Room Temperature Correction Depending on the installed environment the room temperature sensor may require a cor rection The settings may be changed as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 31 00 Lower control 01 Slightly...

Page 12: ...unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indicator lamp green Troubleshooting w...

Reviews: