En-4

INSTALLATION WORK

6. 

Installation dimensions

6. 1. 

110 mm or over **

1.5 m or over 

Remote 

controller

Remote controller 

holder

Tapping screw 

(small)

1.8 m or over

(Wallcap)

120 mm or over *

Wall hook 

bracket

110 mm or over **

*    The  distance  between  the  wall  hook  bracket  and  the  ceiling 

should be 120 mm or more.

**  The side next to the sidewall must follow the size indicated in the 

figure.

Indoor unit piping direction

6. 2. 

The piping can be connected in the 6 directions indicated in the following.
When the piping is connected in direction (2) , (3) , (4) or (5), cut along the piping groove 
in the side of the under cover with a hacksaw.

(Rear)

(2)  Right 

outlet

(5)  Left 

outlet

(6)  Left rear 

outlet

(3) Right bottom outlet

(1) Right rear outlet

(4)  Left bottom outlet

Under cover removal

6. 3. 

(1)  Remove  the  screw  caps  and  screws  from  the 

under cover (in each of 3 places).

(2) Lift up the central part of the under cover.
(3) Release the tabs by pressing on the side of the 

under cover (in 2 places on the side).

(4) Remove the under cover while turning it.

(1)

(1)

(1)

Under cover

Screw cap

Screw

(4)

(4)

(3)

(2)

 Under cover installation

6. 4. 

(1) Push the tabs on the side of the under cover into 

the base (in 2 places on the side).

(2) Press in the top parts of the triangle markings on      

the under cover (in 2 places).

(3) Attach the screws (in 3 places).
(4) Attach the screw caps (in 3 places).

(1)

(1)

(1)

(2)

(2)

Cutting the knockout hole

6. 5. 

Cutting the knockout hole for piping on under cover:
The piping can be connected in the 6 directions indicated in the following. 
When the piping is connected in direction (2), (3), (4) or (5), use a cutting tool to cut along 
the groove for the piping that will coming out of the under cover.

For (5) Left outlet

For (4) Left bottom outlet

For (3) Right bottom outlet

For (2) Right outlet

Cutting the hole in the wall for the connecting piping

6. 6. 

(1)  Cut a 65 mm diameter hole in the wall at the position shown in the following.
(2)  Cut the hole so that the outside end is lower (5 to 10 mm) than the inside end.
(3)  Always align the center of the wall hole. If misaligned, water leakage will occur.
(4)  Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap with 

vinyl tape, and stick the pipe through the hole.

(5)  For left piping and right piping, cut the hole a little lower so that drain water will 

ß

 ow 

freely. 

Wall

Fasten with 
vinyl tape

65 mm dia. hole

65 mm dia. hole

Wall hook bracket

Center mark

Center mark

Wall cap*

Wall pipe*

(Inside)

(Outside)

5 to 10 mm low

*Field supplied

 WARNING

If the wall pipe is not used, the cable interconnecting the indoor unit(s) and outdoor unit 
or branch box may touch metal and cause electric discharge.

Installing the wall hook bracket

6. 7. 

(1) Install the wall hook bracket so that it is correctly positioned horizontally and vertically. 

If the wall hook bracket is titled, water will drip to the 

ß

 oor.

(2)  Install  the  wall  hook  bracket  so  that  it  is  strong  enough  to  support  the  weight  of  the 

unit.

• Fasten the wall hook bracket to the wall with 5 or more screws through the holes near the 

outer edge of the bracket.

• Check that there is no rattle at the wall hook bracket.

Wall hook bracket

Tapping screw

 CAUTION

Install the wall hook bracket level, both horizontally and vertically.

Summary of Contents for AOYG14LTCN

Page 1: ... Swedish Polish AIR CONDITIONER ASENNUSOHJE SISÄYKSIKKÖ seinälle asennettava malli Vain valtuutetuille huoltohenkilöille INSTALLASJONSVEILEDNING INNENDØRSENHET veggmontert modell Kun for autorisert servicepersonell INSTALLATIONSHANDBOK INOMHUSENHET väggmonterad Endast för auktoriserad servicepersonal INSTRUKCJA MONTA U URZ DZENIE WEWN TRZNE do monta u ciennego Do u ytku wy cznie przez autoryzowany...

Page 2: ...use damage or malfunction of your property ABOUT THE UNIT 2 Precautions for using R410A refrigerant 2 1 The basic installation work procedures are the same as conventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools a...

Page 3: ...s to secure refrigerant piping ELECTRICAL REQUIREMENT 4 The indoor unit is powered from the outdoor unit or branch box Do not power indoor unit from separate power source WARNING Refer to local codes for acceptable cable type Cable Cable size Remarks Connection cable Type 60245 IEC 57 3 cable Ground 1 Ø 230 V Max Cable Length Limit voltage drop to less than 2 Increase cable gauge if voltage drop i...

Page 4: ...g When the piping is connected in direction 2 3 4 or 5 use a cutting tool to cut along the groove for the piping that will coming out of the under cover For 5 Left outlet For 4 Left bottom outlet For 3 Right bottom outlet For 2 Right outlet Cutting the hole in the wall for the connecting piping 6 6 1 Cut a 65 mm diameter hole in the wall at the position shown in the following 2 Cut the hole so tha...

Page 5: ... and left rear piping align the marks on the wall hook bracket and shape the connection pipe Bend the connection piping at a bend radius of 70 mm or more and install no more than 35 mm from the wall After passing the indoor piping and drain hose through the wall hole hang the indoor unit on the hooks at the top and bottom of the wall hook bracket No gap Hexagonal wrench Drain cock Drain cap Instal...

Page 6: ... line Type 245 IEC57 Inter unit OUTDOOR UNIT or BRANCH BOX Please connect it to the speciÞed terminal INDOOR UNIT TERMINAL Power line Control line Indoor unit wiring 7 2 1 Remove the wire cover Remove the 1 screw 2 Remove the cable clamp Remove the 1 screw 3 Bend the end of the connection cable as shown in the Þgure 4 Connect the end of the connection cable fully inserting into the terminal block ...

Page 7: ...e Connection cable Pipe Drain hose Check the following GOOD Drain hose Saddle Lifted up Wave End in water Drain hose Connection pipe Wall pipe Connection cable Left piping For connection from the left rear NO GOOD NO GOOD NO GOOD Pipe Connection pipe heat insulation Bind the pipes together so that there is no gap Indoor unit pipe heat insulation FRONT PANEL REMOVAL AND INSTALLATION 9 Intake grille...

Page 8: ...R UNIT PCB TERMINAL Front panel installation 9 4 1 First Þt the lower part of the front panel and insert top and bottom hooks 2 top sides 7 bottom sides 2 center Indoor unit Bottom holes 3 position Bottom hooks 3 position Bottom holes 4 position Center holes 2 position Center hooks 2 position Top hooks 2 position Top holes 2 position Indoor unit Front panel Bottom hooks 2 position Bottom hooks 2 p...

Page 9: ...CN8 Relay wire Notice 2 Clasp Connector CND01 Relay control board Clasps 2 Notice the installing direction of the relay control board The elevation of the control box is fit for the recess of the relay control board 1 Insert the relay control board toward 2 clasps 2 Then set the board with the clasp 3 Connect the relay wire terminal to the connector CND01 on the relay control board 4 Connect the r...

Page 10: ...ding on the installed environment the room temperature sensor may require a cor rection The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Slightly lower control 01 Lower control 02 Warmer control 03 Function number Setting value Installing the external connect kit terminal sold separately Connect the wire of ex...

Page 11: ...nsor error 7 5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error Heating Room Temperature Correction Depending on the installed environment the room temperature sensor may require a cor rection The settings may be changed as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 31 00 Lower control 01 Slightly...

Page 12: ...unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indicator lamp green Troubleshooting w...

Reviews: