6-2. Model:AOYG12LMCE
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5
7.5
10
15
20
Height difference H (m)
Indoor unit is higher than
outdoor unit *1
15
-
-
-
0.858
0.868
10
-
-
0.929
0.872
0.882
7.5
-
0.960
0.933
0.876
0.885
5
0.992
0.964
0.937
0.879
0.889
0
1.000
0.972
0.944
0.887
0.896
Indoor unit is lower than
outdoor unit *2
-5
1.000
0.972
0.944
0.887
0.896
-7.5
-
0.972
0.944
0.887
0.896
-10
-
-
0.944
0.887
0.896
-15
-
-
-
0.887
0.896
HEATING
Pipe length (m)
5
7.5
10
15
20
Height difference H (m)
Indoor unit is higher than
outdoor unit *1
15
-
-
-
0.896
0.879
10
-
-
0.968
0.890
0.879
7.5
-
0.994
0.968
0.896
0.879
5
1.000
0.994
0.968
0.896
0.879
0
1.000
0.994
0.968
0.896
0.879
Indoor unit is lower than
outdoor unit *2
-5
0.995
0.989
0.963
0.891
0.875
-7.5
-
0.987
0.961
0.889
0.873
-10
-
-
0.959
0.887
0.871
-15
-
-
-
0.878
0.862
- 43 -
OUTDOOR UNIT
AOYG07-14LMCE
Summary of Contents for AOYG07LMCE
Page 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE ...
Page 19: ...6 2 Sound level check point 0 8 m 1 m Microphone Microphone 15 WALL MOUNTED ASYG07 14LMCE ...
Page 35: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE ...
Page 43: ...5 Wiring diagrams 5 1 Models AOYG07LMCE and AOYG09LMCE 39 OUTDOOR UNIT AOYG07 14LMCE ...
Page 44: ...5 2 Model AOYG12LMCE 40 OUTDOOR UNIT AOYG07 14LMCE ...
Page 45: ...5 3 Model AOYG14LMCE 41 OUTDOOR UNIT AOYG07 14LMCE ...