![Fujitsu AOYG07LMCE Design & Technical Manual Download Page 20](http://html.mh-extra.com/html/fujitsu/aoyg07lmce/aoyg07lmce_design-and-technical-manual_2344229020.webp)
7. Safety devices
Type of
protection
Protection form
Model
ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE
Circuit
protection
Current fuse (PCB*)
250 V, 3.15 A
Fan motor
protection
Thermal
protector
program
Activate
105±10°C
Fan motor stop
Reset
90±10°C
Fan motor restart
*PCB: Printed Circuit Board
DESIGN & TECHNICAL MANUAL
- 16 -
WALL MOUNTED
ASYG07-14LMCE
Summary of Contents for AOYG07LMCE
Page 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE ...
Page 19: ...6 2 Sound level check point 0 8 m 1 m Microphone Microphone 15 WALL MOUNTED ASYG07 14LMCE ...
Page 35: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE ...
Page 43: ...5 Wiring diagrams 5 1 Models AOYG07LMCE and AOYG09LMCE 39 OUTDOOR UNIT AOYG07 14LMCE ...
Page 44: ...5 2 Model AOYG12LMCE 40 OUTDOOR UNIT AOYG07 14LMCE ...
Page 45: ...5 3 Model AOYG14LMCE 41 OUTDOOR UNIT AOYG07 14LMCE ...