36
Installation and operating manual “1350-EN”
Heat pump, Split, single service
576
U
Standard values
no, yes
no
Time programme 5 / Cooling
If the installation is fitted with the cooling kit (Only with the cooling kit option)
600
U
Pre-selection (day / week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday…
Mon-Sun
601
U
1st phase On (start)
00 : 00… - -:- -
10 min
6 : 00
602
U
1st phase Off (end)
00 : 00… - -:- -
10 min
22 : 00
603
U
2nd phase On (start)
00 : 00… - -:- -
10 min
- -:- -
604
U
2nd phase Off (end)
00 : 00… - -:- -
10 min
- -:- -
605
U
3rd phase On (start)
00 : 00… - -:- -
10 min
- -:- -
606
U
3rd phase Off (end)
00 : 00… - -:- -
10 min
- -:- -
616
U
Standard values
no, yes
no
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating
programmes. Your customised settings are therefore lost.
Holidays, heating circuit 1
641
U
Preselection
Period 1 to 8
Period 1
642
U
Date holidays start (Day / Month)
01.01… 31.12
1
643
U
Date holidays end (Day / Month)
01.01… 31.12
1
648
U
Heating schedule during the holidays
Frost protection,
Reduced
Frost
protection
Holidays, heating circuit 2
If the installation consists of 2 heating circuits (Only with the 2nd circuit kit option)
651
U
Preselection
Period 1 to 8
Period 1
652
U
Date holidays start (Day / Month)
01.01… 31.12
1
653
U
Date holidays end (Day / Month)
01.01… 31.12
1
658
U
Heating schedule during the holidays
Frost protection,
Reduced
Frost
protection
Heating adjustment, circuit 1
710
U
Comfort ambient temperature setpoint
From reduced temperature
to 35°C
0,5 °C
20 °C
712
U
Reduced ambient temperature setpoint
from frost-free temp… to
comfort temperature
0,5 °C
18 °C
714
U
Frost-free ambient temperature setpoint
from 4°C…
to reduced temperature
0,5 °C
8 °C
716
S
Maximum comfort setpoint
20 °C… 35 °C
1 °C
28 °C
720
I
Heating curve slope (See Figure 41)
0.1... 4
0,02
0.5
721
I
Off-set of the heating curve (See Figure 42)
-4.50 °C… 4.5 °C
0,5 °C
0 °C
726
S
Auto-adaptation of the heating curve (see § 3.3.2)
off, on
on
730
I
Summer/Winter heating limits
8 °C … 30 °C
0,5 °C
18 °C
When the average of the outside temperatures over the past 24 hours reaches 18°C, the regulator switches off the
heating (as an economy measure).
During summer mode, the display shows "Eco".
This function is only active in automatic mode.
Line
Function
Setting range
or display
Setting
increment
Basic