Installation
2.1
Regulation installation and
maintenance conditions
The appliance must be installed and the maintained
by an approved professional in accordance with the
prevailing regulations and code of practice, in
particular:
The legislation on the handling of refrigerants.
2.2
Unpacking and reservations
2.2.1
Receipt
Carefully check, in the carrier’s presence, the
general appearance of the appliances and check
that the outside unit is not laid on its side or back.
In the case of any dispute, state any appropriate
reservations to the carrier in writing within 48 hours
and send a copy of this letter to the After-Sales
service.
2.2.2
Handling
The outside unit should not be laid on its side or back
during transport.
Laying the unit down during transport is likely to
damage the internal tubes and the compressor
suspensions.
Any damage caused by transportation of the unit
lying down is not covered by the warranty.
If necessary the outside unit may be tilted only during
manual handling (to go through a door or use a
staircase).
This operation must be conducted very carefully and
the appliance must be immediately restored to
upright position.
2.2.3
Accessories provided
Accessories provided with the outside unit
(figure 10).
Accessories provided with the hydraulic module
(figure 11)
2.3
Installation position
The choice of the position for installation is
particularly important insofar as any later movement
is a delicate operation requiring the intervention of a
qualified person.
Choose the site of the outside unit and the hydraulic
module after discussion with the customer.
Observe the maximum and minimum distances
between the hydraulic module and the outside unit
(Figure 13); the guarantee of the performances and
the system’s service life depend on this.
2.4
Installation of the outside unit
2.4.1
Installation precautions
F
The outside unit must only be installed
outside (outdoors). If a shelter is required, it
must have broad openings on the 4 walls and
observe the installation clearances (fig. 12).
•
Choose a site that is preferably sunny and sheltered
from strong cold predominant winds (mistral,
tramontana, etc…).
•
The unit must be easily accessible for future
installation and maintenance work (fig. 12).
•
Ensure that it is possible to make the connections to
the hydraulic module easily.
14
Installation and operating manual “1350-EN”
Heat pump, Split, single service
1
3
2
4
Figure 10 - Accessories provided
with the outside unit
8
5
6
7
Figure 11 - Accessories provided
with the hydraulic module
1
Elbow
For draining away the
condensates
2
Plug (x 2)
(Depending
on the model)
3
Flexible
i n s u l a t i o n
plate
For filling the empty
space at the input to the
interconnection cable
4
Hex / Allen
key
To open the valves
5
Bracket
To secure the
hydraulic model
6
Outdoor sensor
To monitor the
outside temp
7
1/2" - 5/8" and/or
1/4" - 3/8" adapter
To connect the
flared connection
and the hydraulic
model
8
Nut (1/2" and/or)
1/4"