- (02 - 08) -
O
U
TD
O
O
R U
N
IT
AO
G0
9-
14
LV
C
N
O
U
TD
O
O
R U
N
IT
AO
G0
9-
14
LV
C
N
MODEL
: AO
G14LVCN
H
H
Height difference H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
5
7.5
10
15
20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15
-
-
-
0.994
0.979
10
-
-
1.012
0.994
0.979
7.5
-
1.000
1.012
0.994
0.979
5
0.969
1.000
1.012
0.994
0.979
0
0.969
1.000
1.012
0.994
0.979
Û
2
Indoor unit is
lower than
outdoor unit.
-5
0.964
0.995
1.007
0.989
0.974
-7.5
-
0.993
1.004
0.986
0.972
-10
-
-
1.002
0.984
0.969
-15
-
-
-
0.974
0.959
COOLING
Pipe length (m)
5
7.5
10
15
20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15
-
-
-
0.951
0.950
10
-
-
0.979
0.967
0.966
7.5
-
0.988
0.983
0.971
0.970
5
0.994
0.992
0.987
0.975
0.974
0
1.002
1.000
0.995
0.983
0.982
Û
2
Indoor unit is
lower than
outdoor unit.
-5
1.002
1.000
0.995
0.983
0.982
-7.5
-
1.000
0.995
0.983
0.982
-10
-
-
0.995
0.983
0.982
-15
-
-
-
0.983
0.982
Summary of Contents for AG G09LVCB series
Page 2: ...1 INDOOR UNIT FLOOR TYPE AG G09LVCB AG G12LVCB AG G14LVCB DTR_AG004E_03 2013 01 21 ...
Page 33: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LVCN AO G12LVCN AO G14LVCN DTR_AO094E_02 2013 01 21 ...
Page 40: ... 02 06 OUTDOOR UNIT AO G09 14LVCN OUTDOOR UNIT AO G09 14LVCN MODEL AO G14LVCN ...
Page 47: ... 02 13 OUTDOOR UNIT AO G09 14LVCN OUTDOOR UNIT AO G09 14LVCN SOUND LEVEL CHECK POINT 88888 ...