2) Embedding the indoor unit in a wall
When embedding the indoor unit in a wall, restrict the movement of the horizontal vane for the
upper air outlet so that it only operates horizontally.
(
... Factory setting)
Setting description
Function number
Setting value
Standard
23
00
(Setting forbidden)
01
In a wall
02
3) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be selected as shown in the table below.
(
... Factory setting)
Setting description
Function number
Setting value
Standard
30
00
Slightly lower control
01
Lower control
02
Warmer control
03
4) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be changed as shown in the table below.
(
... Factory setting)
Setting description
Function number
Setting value
Standard
31
00
Lower control
01
Slightly warmer control
02
Warmer control
03
Summary of Contents for AG G09LVCB series
Page 2: ...1 INDOOR UNIT FLOOR TYPE AG G09LVCB AG G12LVCB AG G14LVCB DTR_AG004E_03 2013 01 21 ...
Page 33: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LVCN AO G12LVCN AO G14LVCN DTR_AO094E_02 2013 01 21 ...
Page 40: ... 02 06 OUTDOOR UNIT AO G09 14LVCN OUTDOOR UNIT AO G09 14LVCN MODEL AO G14LVCN ...
Page 47: ... 02 13 OUTDOOR UNIT AO G09 14LVCN OUTDOOR UNIT AO G09 14LVCN SOUND LEVEL CHECK POINT 88888 ...