ELECTRIC CHARACTERISTICS
9.
Model name
AO
G09LVCA
AO
G12LVCA
AO
G14LVLA
Power supply
Voltage
V
230 ~
Frequency
Hz
50
*1) Max operating current
A
10.0
13.5
Starting Current
A
3.8
5.5
6.4
*2) Wiring Spec.:
Main Fuse (Circuit breaker)
Current
A
20
Power Cable
mm
2
1.5 - 2.5
*3) Limited wiring length :
m
15
11
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring Spec.:
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*3) Limited wiring length :
This is the wiring length in case voltage descent is less than 2%.
When the wiring length becomes long, please select the wiring of a more larger diameter.