8) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Operation/Stop mode
46
00
(Setting prohibited)
01
Forced stop mode
02
9) Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when the
outdoor unit is stopped during cooling operation.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Disable
49
00
Enable
01
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the
setting on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low
speed