CAPACITY COMPENSATION RATE FOR PIPE LENGTH
5.
AND HEIGHT DIFFERENCE
MODEL
: AO
G09LVCA, AO
G12LVCA
Height difference H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
5
7.5
10
15
20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15
-
-
-
0.863
0.846
10
-
-
0.944
0.863
0.846
7.5
-
0.978
0.944
0.863
0.846
5
1.000
0.978
0.944
0.863
0.846
0
1.000
0.978
0.944
0.863
0.846
Û
2
Indoor unit is
lower than
outdoor unit
-5
0.995
0.973
0.939
0.858
0.842
-7.5
-
0.971
0.937
0.856
0.840
-10
-
-
0.934
0.854
0.838
-15
-
-
-
0.794
0.778
COOLING
Pipe length (m)
5
7.5
10
15
20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15
-
-
-
0.915
0.905
10
-
-
0.955
0.922
0.912
7.5
-
0.974
0.959
0.926
0.916
5
0.992
0.978
0.963
0.930
0.920
0
1.000
0.986
0.971
0.937
0.927
Û
2
Indoor unit is
lower than
outdoor unit
-5
1.000
0.986
0.971
0.937
0.927
-7.5
-
0.986
0.971
0.937
0.927
-10
-
-
0.971
0.937
0.927
-15
-
-
-
0.937
0.927
H
H
Summary of Contents for AG*G09LVCA
Page 2: ...1 INDOOR UNIT FLOOR TYPE AG G09LVCA AG G12LVCA AG G14LVCA DTR_AG005E_02 2013 07 19 ...
Page 31: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LVCA AO G12LVCA AO G14LVLA DTR_AO129E_01 2012 12 04 ...
Page 37: ... 02 05 OUTDOOR UNIT AO G09 14LV OUTDOOR UNIT AO G09 14LV MODEL AO G14LVLA ...
Page 45: ... 02 13 OUTDOOR UNIT AO G09 14LV OUTDOOR UNIT AO G09 14LV SOUND LEVEL CHECK POINT 88888 ...