CONTENTS OF FUNCTION SETTING
Follow the instructions in the Local Setup Procedure, which is supplied with the remote controller, in
•
accordance with the installed condition.
After turning on the power, perform the Function Setting by using the remote controller.
The settings may be selected between the following two: Function Number or Setting Value.
•
Settings will not be changed if invalid numbers or setting values are selected.
•
1)
Filter sign
2)
Vertical airflow direction range control
3)
Room temperature control for cooling
4)
Room temperature control for heating
5)
Auto restart
6)
Room temperature sensor switching
7)
Remote controller signal code
8)
External input control
9)
Indoor unit fan control for energy saving for cooling
1) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the
estimated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard (400 hours)
11
00
Long interval (1,000 hours)
01
Short interval (200 hours)
02
No indication
03
2) Vertical airflow direction range control
In a concealed installation, change the setting to "Fixed" (02) to restrict the movement of the upper
air outlet so that the airflow is only towards the horizontal direction.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard
23
00
(Setting prohibited)
01
Fixed (Concealed)
02
3) Room temperature control for cooling
Depending on the installed environment, correction of the room temperature sensor may be
required.
Select the appropriate control setting according to the installed environment.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard
30
00
Slightly lower control
01
Lower control
02
Higher control
03
Summary of Contents for AG*G09LVCA
Page 2: ...1 INDOOR UNIT FLOOR TYPE AG G09LVCA AG G12LVCA AG G14LVCA DTR_AG005E_02 2013 07 19 ...
Page 31: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LVCA AO G12LVCA AO G14LVLA DTR_AO129E_01 2012 12 04 ...
Page 37: ... 02 05 OUTDOOR UNIT AO G09 14LV OUTDOOR UNIT AO G09 14LV MODEL AO G14LVLA ...
Page 45: ... 02 13 OUTDOOR UNIT AO G09 14LV OUTDOOR UNIT AO G09 14LV SOUND LEVEL CHECK POINT 88888 ...