![Fujitsu Siemens Computers Primergy TX200 S3 Options Manual Download Page 42](http://html.mh-extra.com/html/fujitsu-siemens-computers/primergy-tx200-s3/primergy-tx200-s3_options-manual_2344460042.webp)
42
Options Guide
TX200
S3
Replacing the processor
Processors
6.2
Replacing the processor
V
CAUTION!
Only processors of the same type may be used on the system board. The
second processor must have at least the same clock frequency as the
first processor. The server always configures itself to the lower clock
frequency of the two processors. For dual operation, use a suitable multi-
processor operating system.
Ê
Open the server as described in the
chapter “Preparation” on page 19
ff.
Ê
Remove the ventilation duct over the main memory (see
page 28
).
Ê
Standard fans: Remove the standard fans (see
page 32
).
Ê
Redundant fans: Remove the ventilation duct over the system fans (see
page 33
).
Ê
Remove the heat sink holder (see
page 33
).
Ê
Redundant fans: Remove the processor fan holder (see
page 35
).