Installing a second processor
Processors
Server with standard fans
Ê
Remove the heat sink holder (see
figure 18 on page 33
):
Ê
Press the green touch point in the direction of the arrow.
Ê
Lift out the heat sink holder.
Ê
Remove the dummy cover from the heat sink holder (see
figure 19 on
page 34
):
Ê
Press on the dummy cover in the direction of the arrow, unhook it and
remove the dummy cover downward.
V
CAUTION!
Keep the dummy cover for future use. If you remove the processor
again and do not replace it with a new one, reinstall the dummy
cover. This ensures that the system is cooled properly.
Figure 16: Removing the standard fans
Ê
Press the two green touch points in the direction of the arrows.
Ê
Lift out the standard fans.