background image

KSP75-FP-011305(1) 

(13)Scale 

(12)Case 

(11)Indicator 

(10)Adjuster Set Screw 

(9)Adjuster 

Pin of BRW 

9.  Remove  the  old  blade  using  tweezers  and  then  attach  the  New  Blade  to  the 

cleaver.   

 

NOTE:  Place  the  hole  on  the  blade  into  the  pin  of  the  blade  holder  when 

attaching the new blade.   

 

10.  Attach  the  BRW(8)  to  the  blade.  Insert  the  pin  of  BRW  into  upper  hole  of  the 

blade, then tighten the screw of the center of BRW.   

 
 
 
 
 
 

NOTE: Do not over-tighten the screw. 

 
11. Turn back the bottom arm of the Clamp Arm(6) and then close the Arm Cover(5). 

Tighten the 2 screws of the Arm Cover(5).   

12. Attach the Fiber Scrap Collector(4) to the cleaver body. Then attach FDB-05.   
13. Initialize the cleaving counter in internal memory of CT50 with  [Clear Cleaver 

Counter] function in splicer or the smartphone application “

”.   

 
4. Blade Height Adjustment

 

Use ribbon fiber when adjusting blade height. If ribbon fiber is unavailable, use a 
single UV coated SM optical fiber.   
The  blade  height  can  be  controlled  by  the  Adjuster(9).  The  blade  height  goes  up 
when rotating the Adjuster(9) clockwise. The blade height goes down when rotating 
the Adjuster(9) counterclockwise.   
 
1. Set and confirm the Blade Height Dial(1) at position “1”.   
2. Loosen the Adjuster Set Screw(10) by using the hexagon wrench.   
3. Rotate the Adjuster(9) 

180 degrees counterclockwise

.   

 

NOTE:  It  is  important  to  lower  the  blade  height  until  it  can’t  touch  the 

fiber before adjusting the blade height. 

 

4.  Set  the  Case(12)  at  the  side  of  the  cleaver.  Then  set  the  Indicator(11)  at  the 

Adjuster(9) as shown below Fig.4-1.   

 
 
 
 
 
 
 
 
 
 
 
5.  Set  the  prepared  fiber  in  the  cleaver  and  then  try  to  cleave  it  as  you  normally 

would.   

6. If the fiber is cleaved, go to Step7. If not cleaved, 

clockwise the Indicator(11) 

one by one 

and go back to step5.

 Do not rotate it too much.

 

7. Repeat Step5 and Step6 until the fiber is cleaved continuously 3 times.   
8. Remove the Indicator(11) from the Adjuster(9). Then set the Indicator(11) again 

around the center of the scale(13).   

9. Clockwise the Indicator(11) to 

6 long scales

.   

10. Tighten the Adjuster Set Screws(10).   
11. Complete the Blade Height Adjustment.   

 

NOTE

 

(1)If the blade height adjustment is not effective, check the following points.   

Check part 

Countermeasure 

The blade or the Clamp arm is not 

attached at the correct position. 

Check and re-attach these parts.   

The Clamp Arm or the top of the 
blade is dirty. 

Clean these parts.   

Position “1” of the blade is lacked 
locked. 

Change  the  position  of  the  blade  to 

“2” and then try to adjust it.   

The Clamp Arm is worn.   

Replace with a new Clamp Arm. 

 

(2)It is recommended to check the cleave angle using the splicer after step11. 

If the result is not good, adjust the blade height again. 

 

5. Cleaver Disposal 

The CB-08 contains no toxic substances and no recyclable material. If the CB-08 
needs to be disposed, it should be discarded as noncombustible material

 

 

6. Contact Address 

Inquiries  concerning  products  should  be  made  to  the 
nearest sales agency or one of the following: 

Fujikura Europe Ltd. 

C51 Barwell Business Park Leatherhead Road, 
Chessington, Surrey KT9 2NY,UK 
Tel. +44-20-8240-2000    (Service: +44-20-8240-2020) 
Fax. +44-20-8240-2010    (Service: +44-20-8240-2029)

 

URL https://www.fujikura.co.uk 

AFL   

260 Parkway East Duncan, SC 29334, U.S.A. 
Tel. +1-800-235-3423    (Service: +1-800-866-3602) 
Fax. +1-800-926-0007    (Service: +1-800-433-5452) 
P.O.Box 3127 Spartanburg, SC    29304-3127 
URL https://www.AFLtele.com 

Fujikura Asia Ltd. 

438A Alexandra Road, Block Alexandra Techno Park 
#08-03, Singapore 119967   
Tel. +65-6278-8955    Fax. +65-6273-7705

 

URL http://www.fujikura.com.sg 

Fujikura (CHINA) Co., 
Ltd. 

7thFloor,  Hang  Seng  Bank  Tower,1000Lujiazui  Ring 
Road,Pudong New Area Shanghai,ZIP200120,China 
Tel:+86-21-6841-3636      Fax:

 

+86-21-6841-2070 

http://www.fujikura.com.cn 

Fujikura Ltd. 

1-5-1 Kiba, Koto-ku, Tokyo, 135-8512, Japan 
Tel. +81-3-5606-1164    Fax. +81-3-5606-1534 

URL: https://www.fusionsplicer.fujikura.com 

Fig4-1   

Fig3-5 

Summary of Contents for CB-08

Page 1: ...umber Qty Remarks Cleaver blade CB 08 1pc Cleave blade for CT50 Indicator 1pc Used for blade height adjustment Case 1pc There is a scale on the lid Manual 1pc This document 3 Cleaver Blade Replacement 1 If the AD 50 is attached detach it from the cleaver body 2 Rotate the Blade Height Dial 1 to position 1 3 Adjust to Blade Positon 1 with Blade Rotating Dial using the Rotate button or a smartphone ...

Page 2: ...continuously 3 times 8 Remove the Indicator 11 from the Adjuster 9 Then set the Indicator 11 again around the center of the scale 13 9 Clockwise the Indicator 11 to 6 long scales 10 Tighten the Adjuster Set Screws 10 11 Complete the Blade Height Adjustment NOTE 1 If the blade height adjustment is not effective check the following points Check part Countermeasure The blade or the Clamp arm is not a...

Page 3: ...保管はしないで下さい 2 構成品 品名 型番 数量 備考 交換刃 CB 08 1 個 CT50 用 調整用レンチ 1 個 ケース 1 個 刃交換手順書 1 部 本紙 3 刃の交換 1 AD 50 アダプタが付いている場合は取り外してください 2 前面にある刃高調整ダイヤル 1 を 1 番に合わせてください 3 刃のポジション 2 が 1 番であることを確認してください 1番以外の場合は 装 置本体の裏側の刃回転ダイヤルや Rotate ボタンで刃のポジション 2 を 1 番に合わ せてください 4 屑回収箱 FDB 05 を取り外します 5 屑回収装置を固定しているネジ 2 個を緩めて屑回収装置 4 を取り外します 6 切断レバーを開いて刃を切断位置にセットします 7 アーム押さえ 5 を固定しているネジを緩めてアーム押さえ 5 を開き クランプ アーム 6 の下側を上にあげます 注意 切...

Page 4: ...して 切断できるか確認 してください 6 光ファイバが切断できない場合は 調整用レンチ 11 が示しているケース上面の 目盛 13 を目印に 調整レンチ 11 を動かして刃高を上げてください 時計周り に動かすと刃高が上がります 光ファイバが切断できるまで刃の高さを上げて行 きます 光ファイバが切断できたら 7 項へ進みます 注意 目盛は 1 目盛ずつ上げるようにしてください 7 連続して 3 回切断できるか確認してください 切断確認は 毎回新しい光ファイバ を使ってください 3 回連続して切断できない場合は 手順 5 からやり直してくだ さい 8 調整用レンチ 11 を取り外し ケース 12 上の目盛の中央にくるように置き直して ください 9 調整用レンチ 11 を長い目盛で 6 目盛 時計周りに回してください 10 アジャスタ固定ネジ 10 で 刃高が変わらないようアジャスタ 9 を固...

Reviews: