KSP75-FP-011305(1)
(13)Scale
(12)Case
(11)Indicator
(10)Adjuster Set Screw
(9)Adjuster
Pin of BRW
9. Remove the old blade using tweezers and then attach the New Blade to the
cleaver.
NOTE: Place the hole on the blade into the pin of the blade holder when
attaching the new blade.
10. Attach the BRW(8) to the blade. Insert the pin of BRW into upper hole of the
blade, then tighten the screw of the center of BRW.
NOTE: Do not over-tighten the screw.
11. Turn back the bottom arm of the Clamp Arm(6) and then close the Arm Cover(5).
Tighten the 2 screws of the Arm Cover(5).
12. Attach the Fiber Scrap Collector(4) to the cleaver body. Then attach FDB-05.
13. Initialize the cleaving counter in internal memory of CT50 with [Clear Cleaver
Counter] function in splicer or the smartphone application “
”.
4. Blade Height Adjustment
Use ribbon fiber when adjusting blade height. If ribbon fiber is unavailable, use a
single UV coated SM optical fiber.
The blade height can be controlled by the Adjuster(9). The blade height goes up
when rotating the Adjuster(9) clockwise. The blade height goes down when rotating
the Adjuster(9) counterclockwise.
1. Set and confirm the Blade Height Dial(1) at position “1”.
2. Loosen the Adjuster Set Screw(10) by using the hexagon wrench.
3. Rotate the Adjuster(9)
180 degrees counterclockwise
.
NOTE: It is important to lower the blade height until it can’t touch the
fiber before adjusting the blade height.
4. Set the Case(12) at the side of the cleaver. Then set the Indicator(11) at the
Adjuster(9) as shown below Fig.4-1.
5. Set the prepared fiber in the cleaver and then try to cleave it as you normally
would.
6. If the fiber is cleaved, go to Step7. If not cleaved,
clockwise the Indicator(11)
one by one
and go back to step5.
Do not rotate it too much.
7. Repeat Step5 and Step6 until the fiber is cleaved continuously 3 times.
8. Remove the Indicator(11) from the Adjuster(9). Then set the Indicator(11) again
around the center of the scale(13).
9. Clockwise the Indicator(11) to
6 long scales
.
10. Tighten the Adjuster Set Screws(10).
11. Complete the Blade Height Adjustment.
NOTE
:
(1)If the blade height adjustment is not effective, check the following points.
Check part
Countermeasure
The blade or the Clamp arm is not
attached at the correct position.
Check and re-attach these parts.
The Clamp Arm or the top of the
blade is dirty.
Clean these parts.
Position “1” of the blade is lacked
locked.
Change the position of the blade to
“2” and then try to adjust it.
The Clamp Arm is worn.
Replace with a new Clamp Arm.
(2)It is recommended to check the cleave angle using the splicer after step11.
If the result is not good, adjust the blade height again.
5. Cleaver Disposal
The CB-08 contains no toxic substances and no recyclable material. If the CB-08
needs to be disposed, it should be discarded as noncombustible material
6. Contact Address
Inquiries concerning products should be made to the
nearest sales agency or one of the following:
Fujikura Europe Ltd.
C51 Barwell Business Park Leatherhead Road,
Chessington, Surrey KT9 2NY,UK
Tel. +44-20-8240-2000 (Service: +44-20-8240-2020)
Fax. +44-20-8240-2010 (Service: +44-20-8240-2029)
URL https://www.fujikura.co.uk
AFL
260 Parkway East Duncan, SC 29334, U.S.A.
Tel. +1-800-235-3423 (Service: +1-800-866-3602)
Fax. +1-800-926-0007 (Service: +1-800-433-5452)
P.O.Box 3127 Spartanburg, SC 29304-3127
URL https://www.AFLtele.com
Fujikura Asia Ltd.
438A Alexandra Road, Block Alexandra Techno Park
#08-03, Singapore 119967
Tel. +65-6278-8955 Fax. +65-6273-7705
URL http://www.fujikura.com.sg
Fujikura (CHINA) Co.,
Ltd.
7thFloor, Hang Seng Bank Tower,1000Lujiazui Ring
Road,Pudong New Area Shanghai,ZIP200120,China
Tel:+86-21-6841-3636 Fax:
+86-21-6841-2070
http://www.fujikura.com.cn
Fujikura Ltd.
1-5-1 Kiba, Koto-ku, Tokyo, 135-8512, Japan
Tel. +81-3-5606-1164 Fax. +81-3-5606-1534
URL: https://www.fusionsplicer.fujikura.com
Fig4-1
Fig3-5