5-5
FinePix S1500 Service Manual
5. Inspection
Confidential: FUJIFILM Service Center Use Only
Sequence
Item
Mode
Preparations for adjustment
(measurement points, subject, other)
Method of adjustment
(VRs, waveforms, required values)
Measuring
equipment and jigs
15
Current
consumption check
Auto mode
(1) Insert the SD card and set the DC
COUPLER CP-04 and POWER
CABLE JIG to the camera.
(2) Set the power supply voltage.
(3) Set the Mode dial to AUTO mode
and turn the camera on.
(4) After the LCD monitor live image
appears, check the current
consumption.
(5) Set the power switch to OFF.
(6) Disconnect the SD card from the
camera.
(2) 5.00 V±0.05 V
(4) 500 mA or less.
(Stable state => When the IRIS/
FOCUS is not operating.)
If the current consumption exceeds
the above value, it is OK if the
current drops into the standard range
within 10 seconds. If the current is
still outside the standard range after
10 seconds, the camera is faulty.
CR0130900U9
ZJ00580-100
16
Checking standby
current
Power off
(1) Set the DC COUPLER CP-04 and
POWER CABLE JIG to the camera.
(2) Set the power supply voltage.
(3) Check the standby current when the
power is turned OFF.
(2) 5.00 V±0.05 V
(3) 0.5 mA or less
CR0130900U9
ZJ00580-100
17
Shipping
inspection
(Inventory repairs
only)
(1) Mode dial.
(2) SETUP frame no.
(3) Flash.
(4) Battery and cards not inserted.
(5) Internal memory.
(6) Battery cover.
(7) Power off.
(1) AUTO mode
(2) New: The default SETUP frame No.
setting is “Continuous”, but to clear
the number of frames in the frame
number memory to zero, you should
always change the setting to “New”
before turning the camera off.
(3) Pop down
(4) Normal
(5) Check that the internal memory is
formatted.
*Excluding customers camera.
(6) Closed
(7) The power supply is stopped after
the camera's shutdown sequence
ends.