H11 TL transmission format
H11 specifies the transmission format to be used in
transmission via the T-Link with the OPC-VG7-TL
option.
Setting data TL transmission format
0
4W + 4W
1
8W + 8W
For details, refer to Chapter 10 "Control Options."
H12 Parallel system
H12 specifies whether to enable the parallel system
functions using the OPC-VG7-SI (SIR) option.
Setting data Parallel system
0
Disable
1
Enable
For details of this function, contact your Fuji Electric
representative.
H13 Number of slave stations in parallel system
H13 specifies the number of slave stations (excluding
master) available in the parallel system using the
OPC-VG7-SI (SIR) option.
Setting range: 1 to 5
For details of this function, contact your Fuji Electric
representative.
H14 Alarm data deletion
Setting H14 to "1" deletes all the alarm history and
alarm information held in the converter.
After that, the H14 data automatically reverts to "0."
Setting range: 0 or 1
H15 to H18 Current limiter values
(Drive 1 or 2, Brake 1 or 2)
The current limiter values can be specified in two
ways--one using H15 to H18 and the other via the
communications link.
To select those values, use the digital input signals
LMT-CCL
(Cancel current limiters) and
I-LIM
(Switch
current limiter values). For details, refer to the
description of E01 (Terminal [X1] function).
Setting range: (Driving) 0 to 150%
(Braking) -150 to 0%
H19, H20
Current limiter early warning
(Level, Timer)
If the current command value exceeds the current
limiter early warning level specified by H19 and it is
kept for the timer period specified by H20, then the
converter issues the current limiter early warning
(
CUR
).
For details, refer to the description of the Y terminals
functions (E02 to E13).
Setting range: (Level) -150 to 150%
(Timer) 0 to 60 (s)
U codes (User application functions)
U01 (Reserved)
Function code reserved for particular manufacturers. Do
not change the setting from the factory default.
Changing the setting from the factory default could
influence converter running.
Accidents or injury may result.
U02 SX bus station number monitor
This function code applies only when the SX bus option
card (OPC-VG7-SX) is used.
U02 reads out the SX bus station number allocated to
the converter itself by the MICREX-SX, depending
upon the system configuration. (Read-only function)
Note:
The U02 data is displayed in decimal. When
setting the station number with the rotary switches,
however, use the hexadecimal value.
U03 (Reserved)
Function code reserved for particular manufacturers. Do
not change the setting from the factory default.
Changing the setting from the factory default could
influence converter running.
Accidents or injury may result.
6-11