Software specifications
Item
Specifications
Data updating cycle
Minimum 1 ms
Operation
Operation command
Operation command, alarm reset command, X1 command
Operation state
output
Running, power running, regeneration, batch alarm signal, etc.
Function code
The function codes assigned to the link number in the function code list can be
referred to.
Function codes other than the S code may not be changed through communication.
Option function codes
H02, H03
Protective functions
Network communication error (Er4: Network error)
* Minor failure: The Er4 alarm can be controlled with H02 and H03.
* Serious alarm: Immediate alarm
* Minor failure: Signal noise or the like. If noise is not frequent, the Er4 alarm can be controlled with H02 and H03 to
continue operation.
* Serious failure: Serious failure such as hardware failure.
Note:
The data refreshing period depends on the SX bus cycle of MICREX-SX and the task period of the application
program.
9-18