background image

– 1 –

Thank you for your purchasing “Fuji DIGITAL THERMOSTAT.”  Please check that the product is exactly the

one you ordered and use it according to the following instructions. (Please refer to a separate operation

manual for details.) Dealers are cordially requested to ensure the delivery of this Instruction Manual to hands

of the end-users.

NOTICE

The contents of this document may be changed in the future without prior notice.

We paid the utmost care for the accuracy of the contents.  However, we are not liable for direct and indirect

damages resulting from incorrect descriptions, omission of information, and use of information in this docu-

ment.

Instruction Manual

DIGITAL THERMOSTAT

Model : PAS3

INP-TN1PAS3-E

Head Office
11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan

Sales Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan

Phone : +81-42-585-6201, 6202
Fax : +81-42-585-6187, 6189
http://www.fic-net.co.jp

Instruction Manual

Details for operation method and the related documents

Before using the controller, check if the type and specifications are as ordered.

Check that all of the following accessories are included in the package box.

· Digital thermostat mian unit

1 unit

· Instruction manual

1 copy

· Mounting bracket

1 pce.

· Watertight packing

1 pce.

· Thermister sensor (only for the type that the input signal is thermistor)
  Note: The provided thermistor sensor is the sensor dedicated to this equipment.

Check of specifications and accessories

Safety Precautions ...............................................

2

For normal usage .................................................

7

1. Installation/mounting ......................................

8

2. Wiring .............................................................

9

3. Usage ............................................................. 10

4. Operation ....................................................... 11

5. Display shifting method .................................. 12

6. Functions ....................................................... 13

7. List of parameters .......................................... 15

8. Alarm function ................................................ 17

9. Error indications ............................................. 19

Specification ......................................................... 19

PAS3 Model Code ................................................ 19

CONTENTS

Contents

Operation method

Details of alarm functions

Specifications

No.

ECNO:410

TN513439-E

ECNO:1142

Name

DIGITAL THERMOSTAT OPERATION MANUAL

DETAIL DESCRIPTION ABOUT FUNCTIONS

OF ALARM OF DIGITAL THERMOSTAT

Catalogue

Summary of Contents for PAS3

Page 1: ...6201 6202 Fax 81 42 585 6187 6189 http www fic net co jp Instruction Manual Details for operation method and the related documents Before using the controller check if the type and specifications are...

Page 2: ...em equipped with this product is continued heating and the ma chine should be designed to automatically stop heating even if alarm is not issued at the time of failure of this product or due to any ot...

Page 3: ...completed Be sure to check that the distance is kept to avoid electric shock or firing before turning the power ON Keep away from terminals while the circuit is energized in order to avoid an electric...

Page 4: ...and noise A place where the unit is exposed to direct sunlight A place where the heat may be accumulated due to the radiation of heat 2 2 Cautions on installation on panel Insert the mounting bracket...

Page 5: ...5 Standard Vertical mounting flush on the panel This product is horizontal When mounting this product on tilted surface the maximum tilt angle is 30 degree from vertical...

Page 6: ...ortened if full capacity load is connected to the alarm output relay If inductive load such as magnetic switches connected as a alarm output load it is recommended to use Z Trap manufactured by Fuji E...

Page 7: ...fication Confirming that the delivered product is equal to the ordered one Outline dimensions Panel cutout dimensions Mounting method on the panel Basic operation method Set value change method List o...

Page 8: ...el thickness 1 t 8 48 85 84 34 2 1 4 PV SET1 SET2 ALM1 ALM2 22 Panel cutout dimensions Unit mm For mounting close together n controllers For separate mounting Note Watertight feature is unavailable if...

Page 9: ...e of 0 4N m Terminal Connection Diagram 100 to 240 Vac Designation of Wiring Material Wire Gauge AWG28 0 1mm2 to AWG16 1 25mm2 Strip off length 5 to 6 mm Rod terminal Dimension of exposed conductor se...

Page 10: ...et value 1 or alarm set value 2 is displayed in the Operation mode level 1 2 Parameter name or set value is displayed at the time of setup of various parameters level 2 3 4 3 Various warnings are disp...

Page 11: ...ressed The increase decrease speed changes when the or key is kept pressed 1 Select a parameter you want to set by pressing the or key 2 Press the key to display the parameter set value 3 Pressing the...

Page 12: ...4 parameter block When indicating the process value PV SEL Press the once 1 Select the level to which move is to occur by the length of time during which the SEL key is pressed 2 Setup of the alarm se...

Page 13: ...solute value Without Relay de energization Upper limit Lower limit Absolute value With Relay de energization Absolute value With Relay de energization Turn OFF ON the power for the main unit once afte...

Page 14: ...or input and thermocouple input It is fixed depending on what was specified at the time of purchase 3 If the input signal was changed the measuring range should be changed to a value that corresponds...

Page 15: ...k Select whether parameter setup change is permitted or not LoC 0 Setup change is permitted for all parameters LoC 1 No setup change is permitted for all parameters LoC 2 Alarm set value 1 ST1 and ala...

Page 16: ...ayed depending on the type Indicated by 4 The accuracy of alarm delay time and of power ON delay time is less than 1 second 5 A difference of 1 C may arise between the indication and the alarm output...

Page 17: ...able For details see Table 1 Alarm action type codes ON delay setting time ON Alarm OFF ON OFF ON OFF Without ON delay function With ON delay function ON delay function Energizing de energizing functi...

Page 18: ...ions of alarm of Digital Thermostat is prepared Please inquire us when you use this function Caution PV Process value Power ON Lower limit alarm Lower limit alarm with hold Power ON Power OFF Output b...

Page 19: ...t L OFF w When burn out direction brn is set at upper limit H ON Case of lower limit alarm setup q When burn out direction brn is set at lower limit L ON w When burn out direction brn is set at upper...

Reviews: