Fuji Electric PAS3 Instruction Manual Download Page 15

– 15 –

7

List of parameters

100%

0%

3

0

1200

1

2

1

1

Note2

Note2

0

0

H

0

0

5

0

0

0

Note1,2

Note1,2

Note1,2

Note1

Table2

Alarm set value 
1 setup

Set the alarm 1 activation value.
It may be set within the input  range.

Parameter

indication

Level

Level 4

Level 2

Level 3

Parameter name

Function

Default 

setting

Remarks

Input type 

Range lower limit setup 

Selection of input type 

Setup of lower limit of the input range
(set range: 0-1999) 

Setup of upper limit of the input range
(set range: 0-1999) 

Burn-out direction 

Set the swinging direction at the time 
of burn-out.
(set range: upper limit = H, lower limit = L) 

Power ON delay time 

Setup of power ON delay time 
power ON delay:

Delay time until output inhibition is 
canceled after power 
ON (set range: 0-120 seconds)

Alarm type 1 

Select the type of alarm activation.
(set range: 0-8)

Alarm type 2

Setup lock 

Select whether parameter setup 
change is permitted or not. 
LoC = 0: Setup change is permitted for 

all parameters.

LoC = 1: No setup change is permitted 

for all parameters.

LoC = 2: Alarm set value 1 (ST1) and 

alarm set value 2 (ST2) only 
may be set. 

Range upper limit setup 

Alarm 1 hysteresis width 

Set the ON/OFF hysteresis width of 
the alarm output. 
(set range: 0-110%FS of the input range) 

Alarm 2 hysteresis width 

Alarm 1 ON delay time

Set ON delay of the alarm output.
(set range: 0-120 seconds) 

Alarm 2 ON delay time

User SPAN adjustment 

Shift the input SPAN side.
(set range: -50-50%FS of the input range) 

Input filter time constant

 Set the time constant.
(set range: 0-90 seconds) 

PV offset 

Shift the display of the process value (PV).
(set range: -10-10%FS of the input range) 

ST1

ST2

Pn2

PSL

b r n

oPd

PA1

PA2

LoC

PSU

HY1

HY2

Pd1

Pd2

AJS

PdF

POF

AJO

User ZERO adjustment 

Shift the input ZERO side.
(set range: -50-50%FS of the input range) 

Alarm set value 2 setup 

Set the alarm 2 activation value.
It may be set within the input  range. 

Note1

Table2

Table1

Table1

Summary of Contents for PAS3

Page 1: ...6201 6202 Fax 81 42 585 6187 6189 http www fic net co jp Instruction Manual Details for operation method and the related documents Before using the controller check if the type and specifications are...

Page 2: ...em equipped with this product is continued heating and the ma chine should be designed to automatically stop heating even if alarm is not issued at the time of failure of this product or due to any ot...

Page 3: ...completed Be sure to check that the distance is kept to avoid electric shock or firing before turning the power ON Keep away from terminals while the circuit is energized in order to avoid an electric...

Page 4: ...and noise A place where the unit is exposed to direct sunlight A place where the heat may be accumulated due to the radiation of heat 2 2 Cautions on installation on panel Insert the mounting bracket...

Page 5: ...5 Standard Vertical mounting flush on the panel This product is horizontal When mounting this product on tilted surface the maximum tilt angle is 30 degree from vertical...

Page 6: ...ortened if full capacity load is connected to the alarm output relay If inductive load such as magnetic switches connected as a alarm output load it is recommended to use Z Trap manufactured by Fuji E...

Page 7: ...fication Confirming that the delivered product is equal to the ordered one Outline dimensions Panel cutout dimensions Mounting method on the panel Basic operation method Set value change method List o...

Page 8: ...el thickness 1 t 8 48 85 84 34 2 1 4 PV SET1 SET2 ALM1 ALM2 22 Panel cutout dimensions Unit mm For mounting close together n controllers For separate mounting Note Watertight feature is unavailable if...

Page 9: ...e of 0 4N m Terminal Connection Diagram 100 to 240 Vac Designation of Wiring Material Wire Gauge AWG28 0 1mm2 to AWG16 1 25mm2 Strip off length 5 to 6 mm Rod terminal Dimension of exposed conductor se...

Page 10: ...et value 1 or alarm set value 2 is displayed in the Operation mode level 1 2 Parameter name or set value is displayed at the time of setup of various parameters level 2 3 4 3 Various warnings are disp...

Page 11: ...ressed The increase decrease speed changes when the or key is kept pressed 1 Select a parameter you want to set by pressing the or key 2 Press the key to display the parameter set value 3 Pressing the...

Page 12: ...4 parameter block When indicating the process value PV SEL Press the once 1 Select the level to which move is to occur by the length of time during which the SEL key is pressed 2 Setup of the alarm se...

Page 13: ...solute value Without Relay de energization Upper limit Lower limit Absolute value With Relay de energization Absolute value With Relay de energization Turn OFF ON the power for the main unit once afte...

Page 14: ...or input and thermocouple input It is fixed depending on what was specified at the time of purchase 3 If the input signal was changed the measuring range should be changed to a value that corresponds...

Page 15: ...k Select whether parameter setup change is permitted or not LoC 0 Setup change is permitted for all parameters LoC 1 No setup change is permitted for all parameters LoC 2 Alarm set value 1 ST1 and ala...

Page 16: ...ayed depending on the type Indicated by 4 The accuracy of alarm delay time and of power ON delay time is less than 1 second 5 A difference of 1 C may arise between the indication and the alarm output...

Page 17: ...able For details see Table 1 Alarm action type codes ON delay setting time ON Alarm OFF ON OFF ON OFF Without ON delay function With ON delay function ON delay function Energizing de energizing functi...

Page 18: ...ions of alarm of Digital Thermostat is prepared Please inquire us when you use this function Caution PV Process value Power ON Lower limit alarm Lower limit alarm with hold Power ON Power OFF Output b...

Page 19: ...t L OFF w When burn out direction brn is set at upper limit H ON Case of lower limit alarm setup q When burn out direction brn is set at lower limit L ON w When burn out direction brn is set at upper...

Reviews: