8. Keypad operation
8.1 Overview
To operate, commission and set up FRENIC-Lift inverter there are two possibilities: using inverter keypad TP-G1-ELS
or PC. For operation using a PC it is necessary to use the dedicated software
Lift Loader
. This software is free of
charge and can be downloaded from our website www.fujielectric-europe.com.
The keypad is connected to the inverter through the RJ-45 connector. This connection is also used for the connection
with the PC or the lift controller using DCP 3 protocol.
Figure 15: Overview of keypad TP-G1-ELS
Table 17: Keypad keys explanation
Key
Description
Use this key to change between operation and programming mode.
Use this key to move the cursor to the right in programming mode.
In Alarm mode: Alarm reset
In Programming mode: leave and discard the change in the settings.
/
In Programming mode: Function selection inside the menu or change the function
value
In operation mode: changing the set point frequency in keypad operation.
Not for
elevator applications!
In Programming mode: leave and discard the change in the settings.
In Programming mode: Parameter edit or saving
In Operation mode: for choosing the displayed value (and units).
Change between Remote (Terminal control) and Local (keypad operation).
These 3 keys may not be used in lift application. In local mode with these keys the
motor can be started and/or stopped.
Lights while a run command is supplied to the inverter.
Displays the actual used multipliers and/or units used in the
LED-display. The actual units will be indicated by a line below
the unit’s indicator.
LCD-display for showing different information, like operation
status, functions values. The lowest line shoes information
regarding keypad operation.
a) Shows the actual operation status like FWD=UP,
REV=DOWN or Stop = Standstill.
b) Shows the actual operation mode Terminal operation = REM
or via DCP=COMM
Keys: With these keys displayed values can be set or function
values can be changed. Status Led shows inverter status.
LED-display shows the operation values, for example Set point
frequency, actual frequency or alarm codes.