[18]
Figure 10 - Air Compressor
Third-Party Air Assist Systems
If you choose to attach your laser to a 3
rd
party air compressor, make sure to use at least one
stage of air drying and air cleaning (5 micron filter recommended) and limit the input
pressure to no more than 30psi. Low-quality compressed air can damage your focus lens.
Connecting Electrical Power
The FSLaser ProLF 24x18 and available accessories are configured to accept 110VAC at 60Hz.
220VAC units connect to power through an included converter (single-phase 220VAC).
The electrical cord is found among the accessories. The power cord plugs into a C14 power
receptacle located on the right side of the machine in the rear. The laser system itself can be
run off of most circuits without modification. However please be aware that the accessories
will increase the circuit load; the most significant power draw usually comes from the
blower/exhaust system. Consult the manufacturer’s information and manual for the operating
parameters of your exhaust system.