Parameter
Values range/ Default setting/ Comments
System
types
Code
level
Speed
reduction
by
Defines the value (as a percentage) by which
the maximum speed is reduced in the "Speed
reduction to" point.
Setting range: 0 to 100 %
Default setting: depending on system type
FC
Factory
4.6.7
Service code
The service code can be changed once the factory code has been entered. A code
deviating from the standard code can therefore be defined.
Setting range: 1 - 9999
4.7
Factory settings
Parameter
Values range/ Default setting/ Comments
System
types
Code
level
Switching cycle
monitoring
Activate / deactivate switching cycle
monitoring.
Setting range: Yes /
No
Default setting: Yes
All
Service
Max. switching
cycles
When switching cycle monitoring is activated:
maximum number of motor starts permitted
per hour.
Setting range: 1 – 60 /h
Default setting: depending on system type
All
Service
Ramp-up time
Defines the motor's ramp-up time.
Setting range: 3 – 30 s
Default setting: depending on system type
All
Factory