LEDs
Status
Description
FAN
PWR1/PWR2
Solid Green
The fan works properly.
Solid Red
1. A fan fault occurs.
2. The fan model does not match with the system.
3. Not all fans are in position.
STATUS
Solid Green
The system works properly.
Solid Yellow
Off
The temperature reaches the threshold value.
The power module is NOT in the position.
Solid Green
Solid Red
The power module works properly.
A power fault occurs.
MGMT
Off
The MGMT port is NOT connected.
Green
The MGMT port is connected.
Blinking Green
The MGMT port is transmitting or receiving data.
SFP+
Off
The SFP+ port is NOT connected.
Solid Green
The SFP+ port is connected at 1/10G.
Blinking Green
The SFP+ port is transmitting or receiving data at 1/10G.
SFP28
Off
The SFP28 port is NOT connected.
Solid Green
The SFP28 port is connected at 10/25G.
Blinking Green
The SFP28 port is transmitting or receiving data at 10/25G.
QSFP+
Off
The QSFP+ port is NOT connected.
Solid Green
The QSFP+ port is connected at 10/40G.
Blinking Green
The QSFP+ port is transmitting or receiving data at 10/40G.
Off
ID
The locator is controlled by CPLD by default.
Solid Blue
The locator is controlled by O&M personnel remotely.