background image

S5860-20SQ

Step 4: Click 

Login

 to display the web-based configuration page.

Configuring the Switch

Step 1: Connect the computer to the Management port of the switch using the network cable.
Step 2: Set the IP address of the computer to 

192.168.1.x

. (“x” is any number from 2 to 254.)

Configuring the Switch Using the Web-based Interface

?

x

OK

Cancel

General

IP address:

Subnet mask :

D efault gateway :

Yo u   c a n   g e t   I P   s e t t i n g s   a s s i g n e d   a u t o m a t i c a l l y   i f   y o u r   n e t w o r k  

s u p p o r t s   t h i s   c a p a b i l i t y.   O t h e r w i s e ,   y o u   n e e d   t o   a s k   y o u r   n e t w o r k

a d m i n i s t r a t o r   f o r   t h e   a p p r o p r i a t e   I P   s e t t i n g s .

Internet  Protocol Version  4  ( TCP/IPv4) Proper ties

Use the following IP address:

Obtain an IP address automatically

Preferred DNS server:

Alternate DNS server:

Validate settings upon exit

A d v a n c e d . . .

.       .       . 2

1

168

192

0

255

255

255

.       .       .

.       .       .

.       .       .

.       .       .

Obtain DNS ser ver address automatically

Use the following DNS ser ver addresses:

Step 3: Open a browser, type 

http://192.168.1.1

, and enter the default username and password, 

admin/admin

.

IE 8/9/10/11, Google Chrome, Firefox are supported

Login

admin

*****

Summary of Contents for 108710

Page 1: ... Mode Gree n Good Supply Yellow Ov er Load CONSOLE Yellow 100 M S5860 48SC 1F 2F 3F 4F 5F 6F 7F 8F 9F 10F 11F 12F 13F 14F 15F 16F 17F 18F 19F 20F 21F 22F 23F 24F 25F 26F 27F 28F 29F 30F 31F 32F 33F 34F 35F 36F 37F 38F 39F 40F 41F 42F 43F 44F 45F 46F 47F 48F 100G 49F 50F 51F 52F 53F 54F 55F 56F Status ID MGMT CONSOLE 25G STATUS PWR1PWR2 FAN MGMT ID 1 2 3 4 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 ...

Page 2: ...U Green 10G 5G 2 5G 1G On Link Flashing ACT PoE LED Mode Green Good Supply Yellow Over Load CONSOLE Yellow 100M MGMT CONSOLE 25G STATUS PWR1PWR2 FAN MGMT ID 1 2 3 4 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 40G Breakout 25 26 S5860 20SQ 40G FUNC S5860 48SC 1F 2F 3F 4F 5F 6F 7F 8F 9F 10F 11F 12F 13F 14F 15F 16F 17F 18F 19F 20F 21F 22F 23F 24F 25F 26F 27F 28F 29F 30F 31F 32F 33F...

Page 3: ...dware Overview Front Back Panel Ports S5860 20SQ MGMT CONSOLE 25G STATUS PWR1PWR2 FAN MGMT ID 1 2 3 4 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 40G Breakout 25 26 S5860 20SQ 40G FUNC USB CONSOLE QSFP MGMT SFP SFP28 Grounding Cable x1 Power Cord x2 Mounting Bracket x2 M4 Screw x14 M6 Screw x8 M6 Nut x8 Inner Rail x2 Slide Rail x2 ...

Page 4: ...F 7F 8F 9F 10F 11F 12F 13F 14F 15F 16F 17F 18F 19F 20F 21F 22F 23F 24F 25F 26F 27F 28F 29F 30F 31F 32F 33F 34F 35F 36F 37F 38F 39F 40F 41F 42F 43F 44F 45F 46F 47F 48F 100G 49F 50F 51F 52F 53F 54F 55F 56F Status ID USB CONSOLE SFP QSFP28 Status Status Status Status FUNC ID Link ACT Status PWR1 PWR2 1 2 3 4 MGMT CONSOLE AFM S48SC FB AFM S48SC FB AFM S48SC FB AFM S48SC FB MGMT MGMT S5860 24XB U USB C...

Page 5: ... CONSOLE AFM S48SC FB AFM S48SC FB AFM S48SC FB AFM S48SC FB S5860 48SC FUNC S5860 24XB U PoE FUNC MGMT SYS PWR FAN PoE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 PoE FUNC S5860 24XB U Green 10G 5G 2 5G 1G On Link Flashing ACT PoE LED Mode Green Good Supply Yellow Over Load CONSOLE Yellow 100M Buttons Description PoE FUNC Switch the display mode between ...

Page 6: ... 40G Breakout 25 26 S5860 20SQ 40G FUNC Status Status Status Status FUNC ID Link ACT Status PWR1 PWR2 1 2 3 4 MGMT CONSOLE AFM S48SC FB AFM S48SC FB AFM S48SC FB AFM S48SC FB S5860 48SC Grounding Point Grounding Point Fan Slots Fan Slots Dual Power Supplies Dual Power Supplies FAN1 FAN2 PWR1 M1SFANI F Status M1SFANI F Status M1SFANI F Status M1SFANI F Status M1SFANI F Status FAN1 FAN2 FAN3 PWR1 PW...

Page 7: ...nnected Blinking Green The MGMT port is transmitting or receiving data SFP Off The SFP port is NOT connected Solid Green The SFP port is connected at 1 10G Blinking Green The SFP port is transmitting or receiving data at 1 10G SFP28 Off The SFP28 port is NOT connected Solid Green The SFP28 port is connected at 10 25G Blinking Green The SFP28 port is transmitting or receiving data at 10 25G QSFP Of...

Page 8: ...0 48SC S5860 48SC 1F 2F 3F 4F 5F 6F 7F 8F 9F 10F 11F 12F 13F 14F 15F 16F 17F 18F 19F 20F 21F 22F 23F 24F 25F 26F 27F 28F 29F 30F 31F 32F 33F 34F 35F 36F 37F 38F 39F 40F 41F 42F 43F 44F 45F 46F 47F 48F 100G 49F 50F 51F 52F 53F 54F 55F 56F Status ID SFP QSFP28 Status Status Status Status FUNC ID Link ACT Status PWR1 PWR2 1 2 3 4 MGMT CONSOLE AFM S48SC FB AFM S48SC FB AFM S48SC FB AFM S48SC FB STATUS...

Page 9: ...P28 Off The QSFP28 port is NOT connected Solid Green The QSFP28 port is connected at 40 100G Blinking Green The QSFP28 port is transmitting or receiving data at 40 100G Solid Green The system works properly Solid Yellow Solid Blue 1 The temperature reaches the threshold value 2 Different power modules are used together The locator takes effect It is controlled by O M personnel remotely LEDs Status...

Page 10: ...rt is transmitting or receiving data at 10 100 Mbps Solid Green Solid Red The fan works properly Solid Green Indicates the switching state 1 A fan fault occurs 2 The fan model does not match with the system 3 Not all fans are in position PWR FAN PoE MGMT LEDs Status Description Off The RJ45 port is NOT connected Solid Green The RJ45 port is connected at 1 2 5 5 10G Blinking Green The RJ45 port is ...

Page 11: ...n The SFP port is connected at 1 10G Blinking Green The SFP port is transmitting or receiving data at 1 10G SFP28 Off The SFP28 port is NOT connected Solid Green The SFP28 port is connected at 10 25G Blinking Green The SFP28 port is transmitting or receiving data at 10 25G ...

Page 12: ...ot operate it in an area that exceeds an ambient temperature of 50 C Do not install the equipment in a dusty environment The installation site must be free from leaking or dripping water heavy dew and humidity The installation site must be well ventilated Ensure that there is adequate airflow around the switch The switch should be installed at least 1U 44 45mm away from devices to its sides Be sur...

Page 13: ...ch Desk Mounting 1 Attach four rubber pads to the bottom 2 Place the chassis on a desk 1 Secure the mounting brackets to the two sides of the switch with supplied M4 screws Rack Mounting 1 2 3 4 40G Breakou t 25 26 40G ...

Page 14: ... nuts 1 Take a new power module out of the package and confirm the input mode and the input parameters of the power module match the requirements 2 Remove the old power module and take the plane printed with power information as the top panel of the power module Hold the handle of the power module with one hand and hold the end of the power module with the other hand Insert it into the chassis alo...

Page 15: ...ews Grounding the Switch FAN1 M1SFANI F Status M1SFANI F 1 Plug the AC power cord into the power port on the back of the switch 2 Connect the other end of the power cord to an AC power source Connecting the Power FAN2 PWR1 M1SFANI F Status M1SFANI F Status WARNING Do not install power cable while the power is on CAUTION The earth connection must not be removed unless all supply connections have be...

Page 16: ...hernet cable to the RJ45 port of IP cameras IP telephone Access Points AP or other network devices 2 Connect the other end of the Ethernet cable to the RJ45 port of the switch 1 Plug the compatible SFP SFP transceiver into the SFP SFP port 2 Connect a fiber optic cable to the fiber transceiver Then connect the other end of the cable to another fiber device Connecting the SFP SFP Ports ...

Page 17: ...ber transceivers Then connect the other end of the cable to another fiber device Connecting the SFP28 Ports 1 Plug the compatible QSFP transceiver into the QSFP port 2 Connect a fiber optic cable to the fiber transceivers Then connect the other end of the cable to another fiber device Connecting the QSFP Ports ...

Page 18: ...sceivers Then connect the other end of the cable to another fiber device Connecting the QSFP28 Ports S5860 48SC 1F 2F 3F 4F 5F 6F 7F 8F 9F 10F 11F 12F 13F 14F 15F 16F 17F 18F 19F 20F 21F 22F 23F 24F 25F 26F 27F 28F 29F 30F 31F 32F 33F 34F 35F 36F 37F 38F 39F 40F 41F 42F 43F 44F 45F 46F 47F 48F 100G 49F 50F 51F 52F 53F 54F 55F 56F Status ID 1 Insert the RJ45 connector into the RJ45 console port on ...

Page 19: ...ng ACT PoE LED Mode Green Good Supply Yellow Over Load CONSOLE Yellow 100M MGMT SYS PWR FAN PoE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 PoE FUNC S5860 24XB U Green 10G 5G 2 5G 1G On Link Flashing ACT PoE LED Mode Green Good Supply Yellow Over Load CONSOLE Yellow 100M The S5860 series switches support stacking up to 2 switches between the same models t...

Page 20: ... assigned automatically if your network suppor ts this capability O ther wise you need to ask your network administrator for the appropriate IP settings Internet Protocol Version 4 TCP IPv4 Properties Use the following IP address Obtain an IP address automatically Preferred DNS server Alternate DNS server Validate settings upon exit Advanced 2 1 168 192 0 255 255 255 Obtain DNS server address auto...

Page 21: ...ers of the HyperTerminal 9600 bits per second 8 data bits no parity 1 stop bit and no flow control Step 4 After setting the parameters click Connect to enter x Quick Connect Protocol The port may be manually entered or selected from the list Serial Flow Control DTR DSR RTS CTS XON XOFF Save session Show quick connect on startup Open in a tab Connect Cancel COM3 9600 8 None 1 Port Baud rate Data bi...

Page 22: ...ugh ping 2 If the network is reachable try restarting the switch 3 Check if the corresponding service is enabled 1 Ensure the switch ports are in the no shutdown state 2 Check if the switch can read the DDM information 3 Check if the port speed setting is correct 4 Try looping the switch cable Power System Fault Connecting the Switch Remotely Unsuccessfully The Port is not Working the LED Indicato...

Page 23: ...rn within 30 Days from the day you receive your goods This excludes any custom made items or tailored solutions Warranty S5860 series switches enjoy 5 years limited warranty against defect in materials or workmanship For more details about warranty please check at https www fs com policies warranty html Return If you want to return item s information on how to return can be found at https www fs c...

Reviews: