ULYSSE HP 

Unità 

Unit 

2500 

3000 

3600 

5000 

Portata d’aria totale 

Total air flow 

m

3

/h 

2500 

3000 

3600 

5000 

Pressione statica utile 

Useful static pressure 

Pa 

90 

140 

80 

80 

N° ventilator/velocità 

N° fans/speeds 

n° 

2/1 

Potenza installata ventilatori

 

Fans input power 

kW 

1,1 

1,1 

1,1 

1,1 

Corrente massima assorbita dai ventilatori

 

Maximum fans input current 

12,2 

13,6 

14,0 

14,4 

Refrigerante 

Refrigerant 

Tipo 

Type

 

R407C 

Solo con recupero statico 

Only with static recovery 

 

 

Potenza frigorifera recuperata

 (1)

 

Recovery cooling capacity 

kW 

2,80 

3,40 

4,30 

5,00 

Efficienza recuperatore

(1)

 

Recovery efficiency 

41,9 

42,1 

44,5 

50 

Temperatura di uscita dell’aria

(1)

 

Outlet air temperature 

°C 

31,6 

31,6 

31,6 

29,0 

Potenzialità riscaldamento recuperata

 (2)

 

Recovery heating capacity 

kW 

9,70 

11,70 

15,20 

22,20 

Efficienza recuperatore

(2)

 

Recovery efficiency 

46,3 

46,6 

50,5 

52,9 

Temperatura di uscita dell’aria

(2)

 

Outlet air temperature 

°C 

6,6 

6,6 

7,6 

8,9 

Con recupero statico e termodinamico 

With static and thermodynamic recovery 

 

 

Potenza frigorifera pompa di calore

 (1)

 

Heat pump cooling capacity 

kW 

4,80 

5,00 

5,50 

8,00 

Potenza frigorifera totale

 (1)

 

Total cooling capacity 

kW 

7,60 

8,40 

9,80 

13,0 

Temperatura di uscita dell’aria

(1)

 

Outlet air temperature 

°C 

28,7 

28,9 

27,8 

26,2 

Potenza riscaldamento pompa di calore

 (2)

 

Heat pump heating capacity 

kW 

5,20 

5,10 

6,80 

8,80 

Potenza riscaldamento totale

 (2)

 

Total heating capacity 

kW 

14,90 

16,80 

22,0 

31,0 

Temperatura di uscita dell’aria

(2)

 

Outlet air temperature 

°C 

11,3 

11,6 

12,0 

12,0 

Potenza assorbita nominale

(1)

 

Nominal absorbed power 

kW 

2,80 

2,90 

3,70 

4,3 

Corrente assorbita nominale

(1)

 

Nominal absorbed current 

20,4 

22,1 

21,0 

29,3 

Alimentazione elettrica 

Power supply 

 

230V / 1+N+PE / 50Hz

 

Livello di pressione sonora

(3) 

Sound level pressure

 

dB(A) 

65 

66 

66 

67 

 

CONDIZIONI DI RIFERIMENTO

 

 

REFERENCES CONDITIONS

 

 

(1) Condizioni nominali: 
     Temperatura aria esterna T=35°C/50% UR 
     Temperatura aria interna T=27°C/50% UR 

 

(1) Nominal conditions: 

    Outdoor air temperature T=35°C/50% RU 

   Indoor air temperature T=27°C/50% RU

 

 

(2) Condizioni nominali: 
     Temperatura aria esterna T=-5°C/80% UR 
     Temperatura aria interna T=20°C/50% UR 

 

(2) Nominal conditions: 

    Outdoor air temperature T=-5°C/80% RU 

   Indoor air temperature T=20°C/50% RU

 

 

(3) Livello di pressione sonora rilevata in campo  
     libero a 1.5m dall’aspirazione aria rinnovo (ISO3744)

 

 

(3) Sound pressure level measured at 1.5m  

from the renewal air suction in free field (ISO3744)

 

 

 

Summary of Contents for ULYSSE HP 1000

Page 1: ...5 576775 e mail info frostitaly it 1 Recuperatori di calore con pompa di calore integrata Heat recovery units with integrated heat pump ULYSSE HP MANUALE DI INSTALLAZIONE E MANUTENZIONE INSTALLATION A...

Page 2: ...0 1000 1500 2000 2500 3000 3600 5000 Are complying at Machine Directive 98 37 CEE Directive PED 97 23 CE Module D1 Electromagnetic Compatibility Directive 89 336 CEE CONFORMITA DICHIARAZIONE DI CONFOR...

Page 3: ...ALE SONO UTILIZZATI SIMBOLI DAL SEGUENTE SIGNIFICATO IN THIS MANUAL WILL BE USED SOME SYMBOLS LIKE THE FOLLOWING ATTENZIONE per azioni che richiedono particolare cautela ed adeguata preparazione ATTEN...

Page 4: ...rbale d avviamento La documentazione fornita con l unit deve essere consegnata al proprietario affinch la conservi con cura per eventuali manutenzioni o assistenze GENERAL INSTRUCTIONS Before proceed...

Page 5: ...tected room from the bad weather with temperatures included between the 20 C and the 55 C MOVIMENTAZIONE DELL UNITA HANDLING OF THE UNIT Le unit FROST ITALY possono essere movimentate sia con carrelli...

Page 6: ...eguito Raising with crane To use a balance or a forked bars Suitably sturdy rope or straps avoid the use of chains Protections to install among strap and machine to avoid that the structure ruins itse...

Page 7: ...n the unit and the other equipment or adjacent structures must be observed In this way the air will be free to circulate and will allow a correct operation from side of the unit and it will be possibl...

Page 8: ...36015 Schio Vicenza Italy Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 8 SCHEMA INSTALLAZIONE A SOFFITTO ROOF INSTALLATION SCHEME 1 0 N 4 SCREW LOCKNUT ISOLATOR SCHEMA INSTALLAZIONE A...

Page 9: ...re negli appositi fori ricavati nei piedini d appoggio dei supporti antivibranti seguendo lo schema indicato di seguito Rubber anti vibrating dampers At the end to avoid the transmission of vibrations...

Page 10: ...NG ULYSSE HP RIPRESA ARIA INTERNA A1 SUCTION INDOOR AIR ESPULSIONE ARIA INTERNA A2 INDOOR AIR EXPULSION INGRESSO ARIA RINNOVO B1 INLET RENEWAL AIR MANDATA ARIA RINNOVO B2 DELIVERY RENEWAL AIR Modello...

Page 11: ...prevenire l entrata di odori ed insetti The drainage system should features and adequately sized siphon to ensure free condensate drainage prevent the inadvertent entry of air into the circuit under...

Page 12: ...Tutte le unit FROST ITALY sono predisposte per il controllo e il monitoraggio remoto della macchina Per ricavarsi il numero dei morsetti per il collegamento remoto fare riferimento allo schema elettr...

Page 13: ...ID3 12 ID4 10 13 ID1 14 ID2 Il terminale remoto fornito assieme all unit Utilizzare un cavo schermato bi polare da 1 5mm2 per collegare i morsetti 88 89 con il terminale remoto The remote display is e...

Page 14: ...a tolerance of the 10 of the nominal tension of power supply of the unit indicated on the panel of the electrical board 230V 10 To verify the connections of the conductors of power supply and their s...

Page 15: ...livello di rumorosit del compressore non sia superiore al normale e che la pressione di mandata sia superiore alla pressione di aspirazione in caso contrario controllare la sequenza delle fasi di ali...

Page 16: ...azione dell unit Controllare lo stato di serraggio dei morsetti di connessione dei cavi elettrici di potenza e di segnale Cura del centro assistenza autorizzato Verificare che i valori di tensione rie...

Page 17: ...essere eseguita da personale frigorista specializzato Il fluido frigorigeno e l olio lubrificante contenuti nel circuito dovranno essere recuperati in accordo con le norme vigenti nel Vostro Paese The...

Page 18: ...otenzialit riscaldamento recuperata 2 Recovery heating capacity kW 1 75 2 50 4 10 6 90 8 90 Efficienza recuperatore 2 Recovery efficiency 51 8 49 6 49 0 54 8 52 9 Temperatura di uscita dell aria 2 Out...

Page 19: ...calore 1 Heat pump cooling capacity kW 4 80 5 00 5 50 8 00 Potenza frigorifera totale 1 Total cooling capacity kW 7 60 8 40 9 80 13 0 Temperatura di uscita dell aria 1 Outlet air temperature C 28 7 2...

Page 20: ...the safety guard and in the air space Check the correct wiring of the electrical supply if it is three phase respect the correct position of the neutral and the phases CONTROLLI MENSILI MONTHLY CONTR...

Page 21: ...FROST ITALY s r l Via Trasimeno 46 int 1 Z I 36015 Schio Vicenza Italy Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 21...

Reviews: