Fronius SnapINverter
General
IMPORTANT!
Settings in the "Meter" menu item may only be entered by staff
trained to do so!
The service password must be entered for the "Meter" menu item.
Three-phase or one-phase Fronius Smart Meters may be used. In both cases, se-
lection is made via the "Fronius Smart Meter" item. The Fronius Datamanager
automatically detects the meter type.
One primary meter and several secondary meters can be selected. The primary
meter must be configured before a secondary meter can be chosen.
Connect to
Fronius
Datamanager
Access Point:
1
Select the "Setup" menu on the inverter display and activate the "WLAN Ac-
cess Point".
2
Establish the connection to the inverter in the network settings (the inverter
is displayed with the name "Fronius_240.XXXXXX").
3
Enter password: 12345678 and confirm.
4
In the browser's address bar, enter the IP address
and confirm.
The Fronius Datamanager start page appears.
LAN:
1
Connect the Fronius Datamanager and computer with a LAN cable.
2
Switch the Fronius Datamanager IP switch to position "A".
3
In the browser's address bar, enter the IP address
confirm.
Configure Froni-
us Smart Meter
as primary meter
1
Call up the Fronius Datamanager website.
-
Open web browser.
-
In the browser's address bar, enter the IP address (IP address for WLAN:
192.168.250.181, IP address for LAN: 169.254.0.180) or enter and con-
firm the host and domain name of the Fronius Datamanager.
-
The Fronius Datamanager website appears.
2
Click on the “Settings” button.
3
Log in to the login area with user "Service" and the service password.
4
Call up the "Meter" menu area.
5
Select the primary meter from the drop-down list.
6
Click on the “Settings” button.
7
Set the meter position of the meter (feed-in point or consumption point) in
the pop-up window. For more information on the position of the Fronius
Smart Meter, see
.
8
Set the converter ratio and the network type.