phases are connected, as the line voltage phases must match the current phases
for accurate power measurement.
Connecting data
communication
cables to invert-
ers
Fronius SnapINveter:
Connect the data communication ports of the Fronius Smart Meter to the Froni-
us system monitoring in the inverter. Several Smart Meters can be installed in the
system, see chapter
Multi meter system - Fronius SnapINverter
1
Connect
D-
to
D-
.
2
Connect
D+
to
D+
.
3
Connect
-
to
-
.
Fronius GEN24 inverter:
Connect the data communication ports of the Fronius Smart Meter to the Mod-
bus interface of the Fronius GEN24 inverter. Several Smart Meters can be in-
stalled in the system, see chapter
Multi meter system - Fronius GEN24 inverter
on page
1
Connect
D-
to
M1-
.
2
Connect
D+
to
M1+
.
3
Connect
-
to
GND
.
14