1. Machine does not work
Mains switch is ON, but relevant operating status LED and digital displays are not lit up
Cause:
Break in mains lead, Mains plug is not plugged in
Remedy:
Check mains lead, and mains voltage if necessary
Cause:
Mains fuse is faulty
Remedy:
Change the fuse
Ursache:
Mains power socket or plug is faulty
Remedy:
Replace any faulty parts
Troubleshooting
Troubleshooting
Safety
WARNING!
An electric shock can be fatal. Before opening up the machine
-
Switch the mains switch to the “O” position
-
Unplug the machine from the mains
-
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
-
Using a suitable measuring instrument, check to make sure that electrical-
ly charged components (e.g. capacitors) have been discharged
CAUTION!
Inadequate PE conductor connections can cause serious injury and
damage. The housing screws provide a suitable PE conductor connection for
earthing (grounding) the housing and must NOT be replaced by any other
screws which do not provide a reliable PE conductor connection.
Displayed service
codes
If any error message that is described here appears on the displays, then the fault is one
that can only be put right by a service technician. Make a note of the error message
shown in the display, and of the serial number and configuration of the power source,
and get in touch with our after-sales service, giving them a detailed description of the
error.
Error is reported by TMS16 board
Err 002
Temperature-sensor short circuit
Err 003
Break in temperature-sensor circuit
Err 006
I command-value compensation error
Err 007
RAM access error
Err 008
SEEPROM access error
Err 009
Secondary overvoltage error
Err 012
ADC offset error
Err 013
ADC gain error
Err 017
Primary overcurrent error
Err 018
Supply voltage error (+5V, +15V)
Err 021
Stack-Overflow
U-P
Primary overvoltage