11
Fig. 11
Functional sequence in 4-step operating mode - without intermediate lowering
Start of cycle
Gas pre-flow time
Current rise via up-slope
Current drop via
down-slope
Gas post-flow time
End of welding
Crater-fill current I
E
Pull back torch trigger and hold it down
Release the torch trigger
Release the torch trigger
Arc ignition with start arc I
S
Welding with pre-set
main current I
H
Pull back torch trigger and hold it down
I
S
I
H
I
E
I
t
-
In the manual or automatic welding modes, for flawless welding joints
-
Pre-settable parameters such as gas pre-flow, start arc, upslope time, main current,
downslope time, crater-fill cur-rent and gas post-flow time
-
In the "PRESETTINGS LEVEL ___" program level (see section headed “Working
with the program-levels”) (TIG parameters), SFS must be set to OFF
Functional sequence
1. Pull back and hold trigger
-
Gas pre-flow time elapses
-
Arc ignites with the pre-set start-arc current I
S
(with HF ignition; HF cuts out automa-
tically after the ignition cycle)
-
LED (9) lights up
2. Release trigger
-
Welding current rises via the pre-set upslope to the value set on dial (15) for the
welding current I
H
-
LED (10) lights up
3. Pull back and hold trigger again
-
Welding current drops via the downslope set on dial (11) to the value set for the
crater-fill current I
E
on dial (16)
-
LED (12) lights up
4. Release trigger
-
Arc goes out
-
Internally pre-set gas post-flow time elapses
4-step mode -
without interme-
diate lowering