![Fronius TransTig 1600 Operating Instructions And Spare Parts List Download Page 34](http://html1.mh-extra.com/html/fronius/transtig-1600/transtig-1600_operating-instructions-and-spare-parts-list_2339440034.webp)
16
Service-menu
Level P1
Service-menu with various test programs
You can find a detailed description of the service menu in the Operating Instructions
“Set-up functions / Error indications”, which are available as on option (42,0410,0494).
-
With button (4) pressed, switch on the machine
-
--- appears
-> “Presettings“ level
-
Press and hold down the torch trigger until
1. P1 appears
-> Service-menu level
2. P1 appears
-> Codelock level
3. --- appears again
-> Presettings level
-
Release button (4)
Working with the program levels
Accessing the
relevant program
level
Presettings
level ---
Use button (4) to select the parameters, and the torch trigger to change their values.
Only the parameters for the operating mode that is set (TIG/ Electrode) are shown.
Parameters for TIG operating mode DC
GAS
Gas pre-flow 0-20s.
G-L
Gas post-flow at I
min
2,0-26s.
G-H
Gas post-flow at I
max
2,0-26s.
UPS
Up-slope 0,1-7s.
SCU
Start Current - Start arc 0-100%
I3
Reduced current, 0-100% of I
H
HFt
Time of HF-period (from 0,01-0,4s)
SCU
Starting current - As absolute value of max. main current (160A/170A)
As relative value of pre-set main current
StS
Special 2-step mode ON/OFF
SFS
Special-4-step mode OFF/1/2/3/4/5
ELd
Diameter of tungsten electrode (from 0-3,2mm)
PRO
Program - For storing the parameters, once these have been set, by pressing the
torch trigger
FAC
Factory - For activating the parameters pre-set by Fronius, by pressing the torch
trigger
Parameters for electrode operating mode
Hti
Hotstart time
0,2-2s
HCU
Hotstart current
0-100%
dYn
Arcforce dynamic
0-100A
PRO
Program - For storing the parameters, once these have been set, by pressing the
torch trigger
FAC
Factory - For activating the parameters pre-set by Fronius, by pressing the torch
trigger.
Parameters of the pre-set Fronius-program
(FAC)
GAS
0,4s
SCU
rEL
G-L
5,0s
StS
OFF
G-H
15,0
SFS
OFF
UPS
1,0s
ELd
2,4mm
SCU
29%
Hti
0,5s
I3
50%
HCU
50%
HFt
0,01s
dyn
30A