hot | H2O
The coolant temperature is too high
Allow cooling unit and cooling circuit to cool down, until "hot | H2O"
is no longer displayed. Open the cooling unit and clean the cooler,
check fan is working properly. Robot interface or field bus coupler:
before resuming welding, set the "Source error reset" signal.
Cause:
Remedy:
no | Prg
No preconfigured program has been selected
Select a configured program
Cause:
Remedy:
no | IGn
"Ignition time-out" function is active; current did not start flowing
before the length of wire specified in the set-up menu had been fed.
The power source safety cut-out has tripped
Shorten the free wire end, press the torch trigger again; clean the
workpiece surface; if necessary, set the "Ito" parameter in the Setup
menu
Cause:
Remedy:
EPG | 17
The welding program selected is invalid
Select valid welding program
Cause:
Remedy:
EPG | 29
The required wire-feed unit is not available for the selected charac-
teristic
Connect correct wire-feed unit, check plug connections for the
hosepack
Cause:
Remedy:
EPG | 35
Measurement of the welding circuit resistance failed
Check grounding cable, current cable or hosepack and replace if ne-
cessary; remeasure welding circuit resistance
Cause:
Remedy:
no | GAS
The Gas watchdog option has detected that there is no gas pressure
Connect a new gas cylinder or open the gas cylinder valve/pressure
regulator, restart "Gas watchdog" option, reset "no | GAS" error mes-
sage by pressing any button.
Cause:
Remedy:
Displayed ser-
vice codes in
connection with
OPT Easy Docu-
mentation
no | dAt
Welding is not possible.
Date and time are not set on the power source
To reset the service code, press the arrow key;
Set the date and time in the 2nd level of the service menu;
see page
Cause:
Remedy:
bAt | Lo
Welding is possible
The battery of OPT Easy Documentation is low
To reset the service code, press the arrow key;
Contact service (to change the battery)
Cause:
Remedy:
115
EN
Summary of Contents for TransSteel 3500 Syn
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 29: ...Control elements and connections 29...
Page 30: ...30...
Page 38: ...38...
Page 39: ...Installation and commissioning 39...
Page 40: ...40...
Page 61: ...Welding 61...
Page 62: ...62...
Page 84: ...84...
Page 85: ...Easy Documentation 85...
Page 86: ...86...
Page 91: ...Setup settings 91...
Page 92: ...92...
Page 103: ...10 Fit the gas nozzle back onto the welding torch 103 EN...
Page 105: ...Troubleshooting and maintenance 105...
Page 106: ...106...
Page 119: ...Appendix 119...
Page 120: ...120...
Page 144: ......