An invalid welding process was called up on the robot interface (no.
37) or an empty flag was selected (no. 32)
Call up a valid welding process or select assigned "Save" button
Cause:
Remedy:
ELn | 8
The connected wire-feed unit is not supported
Connect supported wire-feed unit
Cause:
Remedy:
ELn | 12
Different control panels for selecting materials are in the system
Connect similar control panels to select materials
Cause:
Remedy:
ELn | 13
Invalid change of welding process during welding
During welding do not carry out any illegal change of the welding pro-
cess, reset error message by pressing any button
Cause:
Remedy:
ELn | 14
More than only one robot interface is connected
Only one robot interface may be connected, check the system config-
uration
Cause:
Remedy:
ELn | 15
More than only one remote control unit is connected
Only one remote control unit may be connected, check the system
configuration
Cause:
Remedy:
Err | IP
The power source control has detected a primary overvoltage
Check the mains voltage.
If the service code is still present, turn off the power source, wait 10
seconds, and then turn on the power source.
If the fault persists, contact After-Sales Service
Cause:
Remedy:
Err | PE
The earth current watchdog has triggered the safety cut-out of the
power source.
Switch off the power source
Place the power source on an insulating surface
Connect the grounding (earthing) cable to a section of the workpiece
that is closer to the arc
Wait for 10 seconds and then switch the power source on again
If you have tried this several times and the error keeps recurring,
contact After-Sales Service
Cause:
Remedy:
Err | Ur
If the VRD option is available, the open circuit voltage limit of 35 V
has been exceeded.
Switch off power source
Wait for 10 seconds and then switch the power source on again
Cause:
Remedy:
111
EN
Summary of Contents for TransSteel 3500 Syn
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 29: ...Control elements and connections 29...
Page 30: ...30...
Page 38: ...38...
Page 39: ...Installation and commissioning 39...
Page 40: ...40...
Page 61: ...Welding 61...
Page 62: ...62...
Page 84: ...84...
Page 85: ...Easy Documentation 85...
Page 86: ...86...
Page 91: ...Setup settings 91...
Page 92: ...92...
Page 103: ...10 Fit the gas nozzle back onto the welding torch 103 EN...
Page 105: ...Troubleshooting and maintenance 105...
Page 106: ...106...
Page 119: ...Appendix 119...
Page 120: ...120...
Page 144: ......