![Fronius TransPocket 4000 CEL Operating Instructions Manual Download Page 110](http://html1.mh-extra.com/html/fronius/transpocket-4000-cel/transpocket-4000-cel_operating-instructions-manual_2339431110.webp)
Open circuit voltage (pulsed)
Peak value
Average value
95 V
60 V
Degree of protection
IP 23
Mark of conformity
S, CE
Type of cooling
AF
Insulation class
F
Dimensions l x w x h
625 x 290 x 475 mm
24.6 x 11.4 x 18.7 in.
Weight
37 kg
81.6 lbs
Power source efficiency at 480 A / 39.2 V
89 %
1)
Connected to public grids with 230 / 400 V and 50 Hz
2)
D.C. = Duty cycle
TP 5000 CEL MV
Mains voltage
3 x 200 - 400
V
3 x 380 - 460
V
Mains voltage tolerance
+/- 10%
Mains fuse protection
200 - 240 V: 63 A
380 - 460 V: 35 A
Mains connection
1)
Restrictions possible
Primary continuous
power
100% D.C.
2)
16.3 kVA
Cos phi
0.99
Welding current range
MMA
TIG
10 - 480 A
10 - 480 A
Welding current at
10 min / 40°C
10 min / 40°C
10 min / 40 °C
40% D.C.
2)
60% D.C.
2)
100% D.C.
2)
480 A
415 A
360 A
Standardised working voltage
MMA
TIG
20.4 - 39.2 V
14.5 - 38 V
Maximum working voltage
MMA
48 V (480A)
80 V (10 A)
Open circuit voltage (pulsed)
Peak value
Average value
95 V
60 V
Degree of protection
IP 23
Mark of conformity
S, CE
Type of cooling
AF
Insulation class
F
Dimensions l x w x h
625 x 290 x 475 mm
24.6 x 11.4 x 18.7 in.
Weight
40.5 kg
89.3 lbs
110
Summary of Contents for TransPocket 4000 CEL
Page 2: ......
Page 58: ...58...
Page 112: ...112...
Page 157: ...R glage usine ON 157 FR...
Page 170: ...170...
Page 171: ...171 FR...
Page 172: ......