![Fronius Robacta PTW 1500 Operating Instructions Manual Download Page 43](http://html1.mh-extra.com/html/fronius/robacta-ptw-1500/robacta-ptw-1500_operating-instructions-manual_2339357043.webp)
PTW 1500, PTW
3500
PTW 1500
PTW 3500
Power range
3 - 150 A
3 - 350 A
Maximum value at 60 % d.c.
-
-
Maximum value at 100 % d.c.
150 A
350 A
Pilot arc current
10 A
30 A
Voltage measurement (V-Peak)
113 V
113 V
Striking voltage (Up)
1o kV
1o kV
Plasma gas/shielding gas (EN 439)
Argon
Argon
Hosepack length
4 / 6 / 8 m
4 / 6 m
Electrode diameter
1.6 - 3.2 mm
4.8 - 6.4 mm
Cooling system
Coolant
*)
**)
*)
**)
Cooling power ***)
700 / 1000 /
1300 W
1700 / 1900 W
Min. coolant pressure
3.0 bar
43.50 psi.
3.0 bar
43.50 psi.
Max. coolant pressure
5.5 bar
79.74 psi.
5.5 bar
79.74 psi.
Minimum coolant flowrate
1.0 l/min
1.0 l/min
d.c. = duty cycle
*) Liquid cooling
**) Original Fronius coolant
***) Minimum cooling power in accordance with standard IEC 60974-2
The product complies with standard IEC 60974-7
43
EN
Summary of Contents for Robacta PTW 1500
Page 2: ......
Page 14: ...und Wolframelektrode einrichten 3 1 Wolframelektrode mittels Brennerkappe fixieren 4 14...
Page 34: ...and adjust tungsten electrode 3 1 Fix the tungsten electrode in place using the torch cap 4 34...
Page 44: ...44...
Page 66: ...66...
Page 94: ...Robacta PTW 500 1500 3500 Robacta PTW 500 1 2 3 5 4 1 2x360 3 1 3 2 2 10 mm 3 2 1 3 94...
Page 96: ...10 mm 10mm 1 2 3 3 96...
Page 97: ...PTW 500 1 2 3 4 1 2x360 2 1 2 0 1 3 1 4 97 ZH...
Page 99: ...3 max 3 Nm 1 4 PTW 3500 2 1 2 2 3 1 4 99 ZH...
Page 100: ...1 2 3 4 100...
Page 101: ...5 6 7 30 8 C C ON 9 10 11 101 ZH...
Page 104: ...104...
Page 105: ...105 ZH...