Pilot flow plus connection
Current/shielding gas connection
Water return connection
Cut-out box connections
Water flow connection
Pilot flow minus / plasma gas connection
Plasma torch hosepack: connections
5
When starting up for the first time, make sure the gas flow is correct
6
Position plasma torch (adjust robot)
7
Purge shielding gas and plasma gas for at least 30 seconds
NOTE!
The plasma torch must be cooled constantly during operation.
8
Check that the cooling circuit on the plasma machine is functioning correct-
ly, set the cooling unit to permanent operation (e.g. set-up menu on power
source, parameter C-C =ON)
NOTE!
Igniting the pilot arc without presetting the plasma gas can damage the plasma
nozzle, ceramic centring tube and tungsten electrode (all wearing parts).
9
Specify the plasma gas value (according to the diameter of the plasma nozzle
and the application)
10
Ignite pilot arc
IMPORTANT!
To reduce wear, the pilot arc should burn throughout the operati-
on.
11
Start welding (depending on the application)
36
Summary of Contents for Robacta PTW 1500
Page 2: ......
Page 14: ...und Wolframelektrode einrichten 3 1 Wolframelektrode mittels Brennerkappe fixieren 4 14...
Page 34: ...and adjust tungsten electrode 3 1 Fix the tungsten electrode in place using the torch cap 4 34...
Page 44: ...44...
Page 66: ...66...
Page 94: ...Robacta PTW 500 1500 3500 Robacta PTW 500 1 2 3 5 4 1 2x360 3 1 3 2 2 10 mm 3 2 1 3 94...
Page 96: ...10 mm 10mm 1 2 3 3 96...
Page 97: ...PTW 500 1 2 3 4 1 2x360 2 1 2 0 1 3 1 4 97 ZH...
Page 99: ...3 max 3 Nm 1 4 PTW 3500 2 1 2 2 3 1 4 99 ZH...
Page 100: ...1 2 3 4 100...
Page 101: ...5 6 7 30 8 C C ON 9 10 11 101 ZH...
Page 104: ...104...
Page 105: ...105 ZH...