7
EN
Operating modes
Available opera-
ting modes
Overview of available operating modes. Important additional information on the individual
operating modes can be found in the following sections.
Standard char-
ging / user char-
ging mode
The standard charging / user charging modes should be used for:
-
charging / conservation charging with battery either fitted or removed
-
trickle mode (to charge the battery when consumers in the vehicle are switched on)
User charging:
User charging is an additional charging mode in which charging parameters for the
device can be specified individually. The parameters for user charging mode are preset
in the factory for standby applications (e.g. emergency power systems) or for ambient
temperatures > 35° C (95° F).
Standard charging
For batteries with liquid (Pb, GEL, Ca, Ca silver) and fixed (AGM,
MF, sealant) electrolyte
Refresh charging
For reactivating batteries with liquid (Pb, GEL, Ca, Ca silver) and
fixed (AGM, MF, sealant) electrolyte
User charging
Additional charge mode for batteries with liquid (Pb, GEL, Ca, Ca
silver) and fixed (AGM, MF, sealant) electrolyte
Flash operation
External power supply to consumers and backup for the vehicle
battery
Charge acceptance test
For testing a battery’s ability to accept a charge
Summary of Contents for Acctiva Professional 30A UCN