11
Controls, connections and add-ons
WARNING!
Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described until you have thoroughly read
and understood the following documents:
- these operating instructions
- all the operating instructions for the system components, especially the
safety rules
Driving vehicle
control panel
Driving vehicle FDV 22 MF control panel
(7)
(9)
(1)
(2)
(3)
(4)
(5)
(6)
(8)
(4) SELECT / ENTER button
- Press the button for 3 seconds to enable parameter entry
- To select the desired parameter (3)
- To accept the value set with the +/- buttons.
(5) Control unit ON/OFF toggle switch
For switching the driving vehicle control unit on and off.
(6) Connector for oscillation unit FOU30
For connecting the cable to the optional oscillation unit FOU 30.
(7) Connector for power source control
For connecting the cable to the power source.
(8) Welding ON/OFF toggle switch
For choosing whether to run the automatic program sequence with or without weld
-
ing. Welding can be deactivated for test purposes.
(9) + / - button
For increasing or reducing the parameter value. Press the key for 2 seconds to
increase or reduce the parameter value quickly.
(10)
No. Function
(1) Traverse speed potentiometer
Used to adjust the traversing speed of
the driving vehicle.
Setting range: 5 - 150 cm/min
(2) Digital display
Shows the value of the currently se
-
lected parameter. The digital display is
illuminated.
(3) Parameter selection display field
The selected parameter is signalled
by the relevant LED lighting up. The
currently saved value appears in the
digital display.
Selectable parameters:
Welding segment [cm]
Setting range: 0.5 - 99.9 cm
Pause segment [cm]
Setting range: 0.5 - 99.9 cm
End-crater filling [s]
Setting range: 0.0 - 5 s
Back filling [s]
Setting range: 0.0 - 3 s
All 4 LEDs lit: Total path [cm]
Setting range: 1 - 999 cm
Summary of Contents for 8,045,368
Page 2: ......
Page 52: ...50...
Page 53: ...1 Spare parts...
Page 54: ...2...
Page 55: ...3 Carriage FDV 22 MF Art Nr 8 045 368 incl 48 0005 1217 nur Stecker plug only 48 0005 1182...
Page 58: ...6 Circuit diagram...
Page 59: ...7 EU Declaration of conformity...
Page 60: ...FRONIUS INTERNATIONAL GMBH TechSupport Automation www fronius com addresses www fronius com...