CONTROL PANEL
Figure 1: Console FS31x Generation V01
A = Emergency stop
B = Reset button
C = Indication main switch is turned ON
(Light = ON)
Or
C = Joystick version (Optional with software 1.1 or
last reversion)
D = UP - Film carriage moves upwards
E = DOWN - Film carriage moves downwards
ERRORS
E1: NO PALLET DETECTED 1x beep / pause
E2: EMERGENCY SWITCH
2x beep / pause
After switching on the machine, press RESET!!
E3: INVERTER ERROR
3x beep / pause
E4: CLAMP PROTECTION
4x beep / pause
E5: TABLE SAFETY DEVICE 5x beep / pause
ES:
SERVICE BY FROMM ENGINEER REQUESTED
ALARM RESET
Clear the fault, push the
RESET
button if it is necessary to restart the cycle.
During the failure the machine will repeatedly beep until the fault is cleared.
The relay inside the cabinet will make a clicking noise.
Manual program
From software version 1.1:
Press button shortly and switch from AUTOMATIC to MANUAL program
START button
Automatic program : LED is OFF
Manual program
: LED is blinking
Below parameters have to be sett at first installation. (Can only be changed by FROMM service)
Double wrapping
wrapping ascent / descent
PA08-1
Single wrapping
cycle, ascent only