FS4.1333-Manual-32.11XX.XXX.V04-EN08_R2.doc
FROMM
it is forbidden to duplicate this manual or parts of it in any way or any form without written permission of the author © 2017
website: www.fromm-stretch.com
9
SAFETY DEVICES
We urge on you again that all safety devices are installed for the safety of the operator etc. and
should not be bridged and put out of operation.
Refer to the drawing below for the applied references.
Survey control panel
A = Acoustic signal
B = Emergency stop
C = Light On, when the power
is On Or Joystick
D = Main switch
E = Film tension regulator
film carriage C4
F = Crush-proof guard
G = Crush guard / security
D = Main switch
The main supply (1x230V) is
switched on and off with the
main switch.
The supply voltage for the
control part (24VAC) is thus
equally switched on and off.
E = potential meter for film tension.
E = Adjustment FILM Tension.
(Only when the machine has been equipped with film
carriage 4. Article 16.8663)
F = crush-proof guard
16.8660
This is a mobile crush-proof guard, interlocked by means of
a micro switch.
Any time underlying foreign matter comes into contact with
the guard, it inverts the film carriage's motion and causes the
turntable to stop in phase.
F
E
B
A
D
C