Operating the system
Page 30
B0600008_US
v
3
3.4
Refueling the boiler
3.4.1
Prepare for Fueling
Before opening Insulation Door actual operating mode is “Heating”!
Open Insulation Door
Operating mode "Door open" will
be shown at the Graphic Display
of Boiler Control System
The Induced Draft Fan must
start automatically - you will hear
the noise
Cautiously Open Fuel Loading Chamber Door, keeping face away
from opening
Check the amount of un-burnt fuel within the Filling chamber and de-
cide for refueling in accordance to heat demand (shown by Thermal
Storage System loading status symbol as described above)
3.4.2
Fueling the boiler
Fill up the Fuel Loading Chamber with the desired amount of fuel in
accordance to heat demand (shown by Thermal Storage System
loading status symbol as described above)
Close Fuel Loading Chamber Door