Safety
Page 12
B0600008_US
v
2
2.1
Safety information
Inappropriate use will cause faulty operation of the boiler. The
instructions and information provided in this manual shall be ob-
served.
Detailed information is given in individual instructions for
operation, maintenance and cleaning, as well as troubleshooting. Any
further work shall be carried out by authorized dealer.
Faulty operation conditions (e.g. insufficient combustion air,
non-permitted fuels) will cause serious faults in combustion
(e.g. spontaneous combustion of carbonization gases or
flash fires)!
Instructions and guidelines for system configuration and
minimum operation data values, as well as regulations, standards and
codes for safe and lawful operation together with other
heating components as given in the manuals must be observed!
Inadequate design, installation and maintenance of the flue gas
system will cause insufficient chimney draft and serious faults in
combustion (e.g. spontaneous combustion of wood gases or
flash fires)!
Keep flue system tight and cleaned according to the owner's manual