Safety
Page 14
B0600008_US
v
2
2.1.2
Operation Hazards
NOTICE!
Burn Wood only, max. length 20'' (50cm)!
Load fuel carefully or damage will result!
Build the wood fire directly on the boiler Fuel Loading Chamber refractory
floor!
Do not use small pieces or wood waste that could fall through the Flame Slot
in the refractory.
DANGER!
Risk of Fire or Explosion!
Do not burn coal, fuel coke, garbage and other residual material, painted or
treated wood, gasoline, diesel, fuel oil, naphtha, engine oil, drain oil or
other flammable liquids or any other organic materials or other inappropri-
ate materials!
Do not use chemicals, gasoline, oil or any other combustible fluids to start
the fire!
Use of inappropriate fuels can result in Danger of Life or Severe Injury
caused by explosive combustion and flash fires!
Burn fuels other than those designated in the manual will void warranty
DANGER!
Explosive Gases!
Never open Combustion Chamber Door, Ash-Pit Door, Ash-Pit Cover or
Heat Exchanger Cover during operation or refueling!
Faulty operation of boiler system will cause Danger of Life or Severe Injury
and Property damage!
Flue gases can cause fatal poisoning! In case of strong smell of flue gas:
1. For safety keep all Boiler Doors and Ash-Pit Doors tightly closed!
2. Ventilate the room where boiler is installed!
3. Close the door of the boiler room and doors to living areas!