❒ Remove the geared motor from the back of the boiler
❒ Remove the three back panels
❒ Push the clamping lever (A) to the right, against the spring’s force, and remove the
spring cotter pin and the non-threaded stud
❒ Use the spring cotter pin and non-threaded stud to attach the clamping lever (A)
EFFECT: The more tension is applied to the spring, the more force is applied to clean
the WOS pipes, and the impact is increased.