Servicing the system | 5
B1650222_en | Operating instructions PE1e Pellet
53
Clean the screen on the flushing device (with condensing boiler heat exchanger)
r
Start the shutdown procedure by tapping “Boiler OFF”
r
Allow the boiler to cool for at least one hour
DO NOT switch off the main switch of the boiler.
r
Close the shut-off valve on the water intake
r
Manually activate the flushing device on the controller in order to empty the flushing
line
System menu
Manual
Manual operation
r
In the "Manual operation" menu set the “
calorific value heat exchanger
manual flushing – only in boiler off/standby
” parameter to”
YES
“ for a
few seconds
Ä
The flushing finishes when you exit the menu
r
Remove cover and thermal insulation above the condensing boiler heat exchanger
r
Unscrew the filter cover
r
Remove the screen and thoroughly clean it under running water