Installation
8 – EN
ACT ES 20 – 500
3.4 Instructions for the use of pressure equipment according to PED directive 97/23/EC
To ensure the safe operation of pressure equipments, the user must conform strictly to the above directive
and the following:
1. The equipment must only be operated within the temperature and pressure limits stated on the
manufacturer’s data nameplate.
2. Welding on heat-exchanger is not recommended.
3. The equipment must not be stored in badly ventilated spaces, near a heat source or inflammable
substances.
4. Vibration must be eliminated from the equipment to prevent fatigue failure.
5. Automatic condensate drains should be checked for operation every day to prevent a build up of
condensate in the pressure equipment.
6. The maximum working pressure stated on the manufacturer’s data nameplate must not be exceeded.
Prior to use, the user must fit safety / pressure relief devices.
7. All documentation supplied with the equipment (manual, declaration of conformity etc.) must be kept for
future reference.
8. Do not apply weights or external loads on the vessel or its connecting piping.
TAMPERING, MODIFICATION AND IMPROPER USE OF THE PRESSURE EQUIPMENT ARE
FORBIDDEN. Users of the equipment must comply with all local and national pressure
equipment legislation in the country of installation.
4 Installation
4.1 Transport
Check for visible loss or damage, if no visible damage is found place the unit near to the installation point
and unpack the contents.
To move the packaged unit we recommend using a suitable trolley or forklift truck. Hand carrying is not
recommended.
Always keep the dryer in the upright vertical position. Damage to components could result if unit is laid on
its side or if placed upside down.
Handle with care. Heavy blows could cause irreparable damage.
4.2 Storage
S
C
C
0
00
1
Even when packaged, keep the machine
protected from severity of the weather.
Keep the dryer in vertical position, also when
stored. Turning it upside down some parts could
be irreparably damaged.
If not in use, the dryer can be stored in its
packaging in a dust free and protected site at a
temperature of +34°F (+1°C) … +122°F (+50°C),
and a specific humidity not exceeding 90%.
Should the stocking time exceed 12 months,
please contact the manufacturer.
The packaging materials are recyclable. Dispose of material in compliance with the rules
and regulations in force in the destination country.
Summary of Contents for ACT ES 20-500
Page 15: ...Technical data ACT ES 20 500 15 EN 6 Technical data 6 1 Technical data ACT ES 20 200 1 115 60 ...
Page 16: ...Technical data 16 EN ACT ES 20 500 6 2 Technical data ACT ES 20 500 1 230 60 ...
Page 17: ...Technical data ACT ES 20 500 17 EN 6 3 Technical data ACT ES 200 500 3phase 3 460 60 ...
Page 18: ...Technical data 18 EN ACT ES 20 500 6 4 Technical data ACT ES 200 500 3phase 3 575 60 ...
Page 37: ...Attachments ACT ES 20 500 37 EN 9 1 Dryers dimensions 9 1 1 ACT ES 20 50 ...
Page 38: ...Attachments 38 EN ACT ES 20 500 9 1 2 ACT ES 75 ...
Page 39: ...Attachments ACT ES 20 500 39 EN 9 1 3 ACT ES 100 150 ...
Page 40: ...Attachments 40 EN ACT ES 20 500 9 1 4 ACT ES 200 250 ...
Page 41: ...Attachments ACT ES 20 500 41 EN 9 1 5 ACT ES 300 350 ...
Page 42: ...Attachments 42 EN ACT ES 20 500 9 1 6 ACT ES 400 500 ...
Page 43: ...Attachments ACT ES 20 500 43 EN 9 1 7 ACT ES 200 250 3phase ...
Page 44: ...Attachments 44 EN ACT ES 20 500 9 1 8 ACT ES 300 350 3phase ...
Page 45: ...Attachments ACT ES 20 500 45 EN 9 1 9 ACT ES 400 500 3phase ...
Page 46: ...Attachments 46 EN ACT ES 20 500 9 2 Exploded views 9 2 1 ACT ES 20 30 ...
Page 47: ...Attachments ACT ES 20 500 47 EN 9 2 2 ACT ES 50 ...
Page 48: ...Attachments 48 EN ACT ES 20 500 9 2 3 ACT ES 75 ...
Page 49: ...Attachments ACT ES 20 500 49 EN 9 2 4 ACT ES 100 ...
Page 50: ...Attachments 50 EN ACT ES 20 500 9 2 5 ACT ES 125 150 ...
Page 51: ...Attachments ACT ES 20 500 51 EN 9 2 6 ACT ES 200 250 ...
Page 52: ...Attachments 52 EN ACT ES 20 500 9 2 7 ACT ES 300 350 ...
Page 53: ...Attachments ACT ES 20 500 53 EN 9 2 8 ACT ES 400 500 ...
Page 54: ...Attachments 54 EN ACT ES 20 500 9 2 9 ACT ES 200 250 3phase ...
Page 55: ...Attachments ACT ES 20 500 55 EN 9 2 10 ACT ES 300 350 3phase ...
Page 56: ...Attachments 56 EN ACT ES 20 500 9 2 11 ACT ES 400 500 3phase ...
Page 65: ...Blank pages ACT ES 20 500 65 EN 10 Blank pages ...
Page 66: ...Blank pages 66 EN ACT ES 20 500 ...