Operating Instructions
(continued)
DRAINAGE:
Fig. 25
CHECK FILTER FEATURE:
This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more
efficient operation. The LED (light) which above the "Filter" button will illuminate
after 250 hours of operation. To reset after cleaning the filter, press the "Filter"
button and the light will go off.
FAULT CODE:
If the display reads "AS" , the room temperature sensor has failed. Contact your Authorized
Frigidaire Service Center.
If the display reads "ES" , the evaporator temperature sensor has failed. Contact your
Authorized Frigidaire Service Center.
If the display reads "E4" , the display panel communication has failed. Contact your
Authorized Frigidaire Service Center.
If the display reads "P1" , bottom tray is full. Carefully move the unit to a drain location, remove
the bottom drain plug and let the water drain away. Restart the machine until the "P1" symbol
disappears. If error repeats, call for service.
Operating Instructions
During the dehumidifying mode, you will need a
garden hose (sold separately) to drain the condensate
from the unit.
Remove the rubber stopper from the hose connector,
then screw on a garden hose to the connector as shown
on Fig. 25.
The hose may then:
A. Discharge into a drain that is lower than the unit.
B. Be connected to a condensate pump (sold separately).
Remove the
supplied rubber
stopper
Garden hose
C. During cooling mode, please replace the rubber stopper
to the hose connector to reach the maximum performance.
SELECTING FAN SPEED:
You can select the desired fan speed, by pressing the FAN SPEED button. The fan
speed will change in the sequence as the drawing on the left.
After choosing the fan speed as "AUTO", “LOW”, “MED” or “HIGH”, the
corresponding fan speed indicator light will illuminate. Under AUTO, Heat, Dry
mode, you can not select the fan speed.
AUTO
LOW
MED
HIGH